Siemens 3RW5235-6TC05 — Soft Starters

Siemens 3RW5235-6TC05 Soft Starter, 68 A min, 200-600 V

MPN3RW5235-6TC05
Active

Siemens SIRIUS 3RW5235-6TC05 soft starter, 68 A minimum, 200-600 V, Trip Class 10A/10E/20E, PROFIBUS, Modbus RTU/TCP, EtherNet/IP, PROFINET, 203 x 185 x 306 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5235-6TC05 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW5235-6TC05 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)75 kW
Rated motor power at 230 V (40 °C)37 kW
Rated operational current at 40 °C248 A
Rated operational current at 50 °C222 A
Rated operational current at 60 °C204 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)1 807 W
3RW5235-6TC05 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typebusbar connection
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputNo
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %
3RW5235-6TC05 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5235-6TC05 — Mechanical
ParameterValue
Height306 mm
Width185 mm
Depth203 mm
Weight6.6 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5235-6TC05 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5235-6TC05 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s
3RW5235-6TC05 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

What this soft starter covers — motor FLA and voltage range

The 3RW5235-6TC05: Trip Class is selectable between CLASS 10A (default), 10E, and 20E per IEC 60947-4-2. For a motor with a 60-second locked-rotor withstand, CLASS 10A clears before the rotor heats past the insulation class; CLASS 20E gives more headroom on high-inertia loads like centrifuges or crushers.

Fieldbus and control — what's onboard

This soft starter ships with PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET standard communication. No separate gateway module needed for most PLC networks — it talks directly to a S7-1500 or CompactLogix over the same cable. PROFIenergy is supported when used with the PROFINET communication module. That lets the controller put the soft starter into a low-power state during production pauses without cycling the main contactor. Control supply voltage is 24 V DC. Remote reset is possible by cycling the control supply off and on.

Mounting and environmental limits

Dimensions are 203 mm deep, 185 mm wide, 306 mm high. Fastening is screw fixing. Mounting position allows a vertical surface with ±90° rotation and ±22.5° tilt forward/back — useful when the panel layout forces an off-angle installation. Operating temperature range is -25…+60 °C, with derating required above 40 °C. Pollution degree 3 per IEC 60947-4-2 means it tolerates conductive dust and humidity typical in industrial enclosures without conformal coating. Clearances: 100 mm above, 10 mm in front, 0 mm behind, 75 mm below, 5 mm at the sides. The zero rear clearance is handy for shallow back panels.

Frequently asked questions

What compliance approvals does the 3RW5235-6TC05 carry?

It carries CE marking, UL approval, and CSA approval. These cover the European Machinery Directive, North American safety standards for industrial control equipment, and Canadian electrical code acceptance.