Skip to main content
Siemens 3RW5245-2TC15 — Soft Starters

Siemens 3RW5245-2TC15 SIRIUS Soft Starter, 135 A, 200-600 V

MPN3RW5245-2TC15
Active

Siemens SIRIUS 3RW5245-2TC15 hybrid soft starter, 135 A minimum, 200-600 V, Class 10A/10E/20E, PROFIBUS/Modbus/EtherNet/IP, screw fixing, 393x210x203 mm.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW5245-2TC15 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW5245-2TC15 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)160 kW
Rated motor power at 230 V (40 °C)90 kW
Rated operational current at 40 °C546 A
Rated operational current at 50 °C483 A
Rated operational current at 60 °C442 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)4 471 W

Control & Connection

3RW5245-2TC15 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typebusbar connection
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputNo
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %

Protection & Features

3RW5245-2TC15 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW5245-2TC15 — Mechanical
ParameterValue
Height393 mm
Width210 mm
Depth203 mm
Weight9.9 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm

Environmental

3RW5245-2TC15 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Specifications

3RW5245-2TC15 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s

Electrical

3RW5245-2TC15 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

135 A minimum, 200-600 V — trip class and duty

The 3RW5245-2TC15 is a SIRIUS hybrid soft starter rated for a minimum operating current of 135 A across a supply range of 200 to 600 V (50/60 Hz). Trip class is configurable as CLASS 10A (default), 10E, or 20E per IEC 60947-4-2, giving the commissioning engineer flexibility to match the motor start profile without changing hardware. The unit supports soft torque and pump ramp down, making it suited for centrifugal loads where mechanical shock on start and water hammer on stop must be minimised.

Fieldbus suite and control integration

Onboard fieldbus options include PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET standard, with PROFIenergy available when paired with the PROFINET communication module. Remote reset is possible by cycling the control supply voltage; auto-reset is also supported, which simplifies integration into automated restart sequences after a fault. Firmware update capability is present, allowing field upgrades without replacing the unit.

Mounting and environmental limits

The unit can be rotated ±90° or tilted ±22.5° front-to-back, which aids panel layout in tight enclosures. Clearance requirements: 100 mm above, 75 mm below, 10 mm forward, 5 mm at the sides, and 0 mm backward — critical for airflow and cable entry planning. Shock resistance is 15 g / 11 ms, with potential contact lifting above 12 g / 11 ms.

The 3RW5245-2TC15 carries CE marking, UL approval, and CSA approval, satisfying the documentation requirements for installations under IEC, NEC, and CEC frameworks. Service factor is 1, meaning the unit is rated for continuous duty at its nameplate current without overload margin — a point to note for applications with sustained overload cycles.

Frequently asked questions

What compliance documentation does Siemens provide for the 3RW5245-2TC15?

The unit carries CE marking, UL approval, and CSA approval as evidenced by the datasheet. These cover the IEC 60947-4-2 standard for soft starters, plus North American installation requirements.

MPN
3RW5245-2TC15