Skip to main content
Siemens 3RW5246-6TC14 — Soft Starters

Siemens 3RW5246-6TC14 SIRIUS Soft Starter, 160 A, 200-480 V

MPN3RW5246-6TC14
Active

Siemens SIRIUS 3RW5246-6TC14 soft starter, 160 A minimum, 200-480 V, Class 10A/10E/20E trip, PROFIBUS/Modbus RTU/Modbus TCP/EtherNet/IP/PROFINET, 393 x 210 x 203 mm.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW5246-6TC14 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW5246-6TC14 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)200 kW
Rated motor power at 230 V (40 °C)110 kW
Rated operational current at 40 °C641 A
Rated operational current at 50 °C568 A
Rated operational current at 60 °C519 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)4 706 W

Control & Connection

3RW5246-6TC14 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typebusbar connection
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputNo
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %

Protection & Features

3RW5246-6TC14 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW5246-6TC14 — Mechanical
ParameterValue
Height393 mm
Width210 mm
Depth203 mm
Weight9.9 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm

Environmental

3RW5246-6TC14 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Specifications

3RW5246-6TC14 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s

Electrical

3RW5246-6TC14 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Motor starting duty and trip class selection

The 3RW5246-6TC14 is a SIRIUS hybrid switching device rated for a minimum motor current of 160 A at a supply voltage range of 200 to 480 V. The trip class is configurable as CLASS 10A (default), 10E, or 20E per IEC 60947-4-2, which governs the allowable thermal overload during acceleration. For a high-inertia load like a centrifuge or large fan, selecting CLASS 20E extends the start time window without nuisance tripping; CLASS 10A is the standard for most pump and conveyor starts. The unit supports soft torque and pump ramp down, which reduces mechanical shock on the load train during start and stop. This is relevant for applications where water hammer or belt stress is a failure mode.

Fieldbus integration and communication options

This soft starter ships with onboard PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET standard communication. PROFIenergy is supported when used with the PROFINET communication module, enabling energy management during idle phases. The device also supports firmware updates in the field. No analog output is present, so closed-loop torque control is not available. The remote reset function is triggered by cycling the control supply voltage.

Panel fit and mounting clearances

Dimensions are 393 mm height, 210 mm width, and 203 mm depth. Required clearances: 100 mm upwards, 75 mm downwards, 10 mm forwards, 5 mm at the side, and 0 mm backwards. Shock resistance is 15 g for 11 ms, with potential contact lifting at 12 g for 11 ms.

Regulatory approvals and compliance documentation

The 3RW5246-6TC14 carries CE marking, UL approval, and CSA approval. Service factor is 1.0. The minimum load is 15% relative to the smallest settable Ie.

Frequently asked questions

What compliance documentation does Siemens provide for the 3RW5246-6TC14?

The unit carries CE marking, UL approval, and CSA approval. Service factor is 1.0.

MPN
3RW5246-6TC14