Siemens 3RW5248-2AC15 Soft Starter, 240 A, 200-600 V, SIRIUS

MPN3RW5248-2AC15
Active

Siemens SIRIUS 3RW5248-2AC15 soft starter, 240 A minimum rated current, 200-600 V AC, Class 10A/10E/20E trip, PROFIBUS, Modbus RTU/TCP, EtherNet/IP, PROFINET, UL, CSA, CE.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW5248-2AC15 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW5248-2AC15 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)315 kW
Rated motor power at 230 V (40 °C)160 kW
Rated operational current at 40 °C987 A
Rated operational current at 50 °C873 A
Rated operational current at 60 °C796 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)8 500 W

Control & Connection

3RW5248-2AC15 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typebusbar connection
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %

Protection & Features

3RW5248-2AC15 — Protection & Features
ParameterValue
Motor overload protectionYes; Electronic motor overload protection
Thermistor motor protectionNo
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW5248-2AC15 — Mechanical
ParameterValue
Height393 mm
Width210 mm
Depth203 mm
Weight10.6 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm

Environmental

3RW5248-2AC15 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Specifications

3RW5248-2AC15 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s

Electrical

3RW5248-2AC15 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

240 A minimum — the load floor that governs motor starting

The 3RW5248-2AC15 is a SIRIUS hybrid switching device with a minimum rated operating current of 240 A, setting the floor for the motor load it can start and protect. Trip class is configurable: default CLASS 10A, with selectable CLASS 10E and CLASS 20E per IEC 60947-4-2. Rated operating voltage spans 200... 600 V AC, covering 208 V, 400 V, and 480 V nominal supplies without a tap change.

Fieldbus fit — PROFIBUS, Modbus, EtherNet/IP, PROFINET

This soft starter ships with onboard PROFIBUS DP, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET standard communication. The PROFINET interface supports PROFIenergy when paired with the PROFINET Standard communication module — useful for coordinated energy management in automated lines. Analog output is configurable as 4... 20 mA (default) or 0... 10 V via the High Feature HMI parameter set. Remote reset is available by cycling the control supply voltage — no fieldbus command required for a simple restart after a fault clears. Firmware updates are supported, and an error logbook is available with special accessories — useful for diagnosing repeated start faults without a laptop at the panel.

Mounting and thermal derating in the panel

Mounting is screw fixing with a vertical surface orientation; the unit can be rotated ±90° and tilted ±22.5° front-to-back. Clearance requirements: 100 mm upwards, 10 mm forwards, 0 mm backwards, 75 mm downwards, and 5 mm at the sides — plan the enclosure depth and gland plate accordingly. Operating temperature range is -25... +60 °C, with derating required at 40 °C or above. In a steel-mill or foundry ambient — where the panel air might hit 50 °C — expect a current derating that must be factored into the motor selection. Shock resistance is 15 g / 11 ms, dropping to 12 g / 11 ms if contact lifting is a concern. Dimensions: 393 mm height, 210 mm width, 203 mm depth — a substantial footprint that fits a standard 600 mm deep enclosure but will crowd a shallow 400 mm panel. The 210 mm width means it occupies three or four DIN-rail module widths depending on the rail layout.

Compliance and approvals — UL, CSA, CE

Carries UL approval, CSA certification, and CE marking — accepted across North America and the European Economic Area without additional testing. The product category is hybrid switching devices, reflecting the combination of electromechanical and semiconductor switching elements inside.

MPN
3RW5248-2AC15