Siemens 3RW5515-1HA04 — Soft Starters

Siemens 3RW5515-1HA04 Soft Starter, 200-480V, Active

MPN3RW5515-1HA04
Active

Siemens 3RW5515-1HA04 soft starter, 200-480 V rated, Trip Class 10A/10E/20E/30E per IEC 60947-4-2, ATEX/IECEx certified, active production.

StockContact for availability
Lead time3-5 Days wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW5515-1HA04 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW5515-1HA04 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)11 kW
Rated motor power at 230 V (40 °C)5.5 kW
Rated operational current at 40 °C43.3 A
Rated operational current at 50 °C39 A
Rated operational current at 60 °C33.9 A
Rated insulation voltage480 V
Minimum settable current (% of Ie)10 %; Relative to set Ie
Power loss during startup (50 °C)309 W

Control & Connection

3RW5515-1HA04 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typescrew-type terminals
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %

Protection & Features

3RW5515-1HA04 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection) / When using the motor overload protection according to ATEX, an upstream contactor is required in inside-delta circuit.
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW5515-1HA04 — Mechanical
ParameterValue
Height275 mm
Width170 mm
Depth152 mm
Weight2.3 kg
Mounting positionVertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°)
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm

Environmental

3RW5515-1HA04 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Specifications

3RW5515-1HA04 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 360 s
Ramp-Down Time Of Soft Starter0 ... 360 s

Electrical

3RW5515-1HA04 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable125 ... 800 %
Starting Voltage [%]20 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Active production, 200-480 V, ATEX-rated

The 3RW5515-1HA04: Rated for 200-480 V supply, this soft starter covers the common low-voltage motor range across North America and Europe. The wide voltage window means it handles 208 V, 230 V, 400 V, and 480 V without a rewire — just set the motor nameplate parameters during commissioning. ATEX and IECEx certification (both Yes) means it's listed for use in potentially explosive atmospheres — not just a general-purpose box. That's a hard requirement for chemical plants, grain elevators, paint lines, and any Zone-classified area. The cert covers the soft starter itself, not just the enclosure.

Trip Class 10A/10E/20E/30E — what that means for your motor

Trip Class 10A (default) means the soft starter disconnects within 10 seconds at locked-rotor current — that's the standard for most general-purpose pumps and fans. Class 10E is a tighter thermal model for European-rated motors. The selector is parameterizable, so you tune it to the load, not the other way around. Voltage ramp, torque control, pump ramp down, and breakaway pulse are all built in — no add-on cards needed. The breakaway pulse is useful for sticky loads like conveyors that need a short torque hit to break static friction before the ramp takes over. DC braking and combined braking are both present — so if the motor needs to stop faster than coast-to-rest, the soft starter can inject DC into the windings. That's a feature normally found on VFDs, not soft starters, and it saves an external braking contactor.

Fieldbus and panel integration

PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP are all on the menu — no separate gateway needed for most plant networks. PROFIenergy is supported when paired with a PROFINET communication module, useful for energy-aware production scheduling. The 170 mm width and 275 mm height fit a standard 600 mm-wide panel section. Depth is 152 mm, so it clears a 200 mm deep enclosure with room for wiring ducts. Clearance requirements: 100 mm above, 75 mm below, 10 mm in front, 5 mm at the sides — plan the gland plate and DIN rail layout accordingly. Screw terminals for power wiring: dual terminals accept 1.0-2.5 mm² and 2.5-10 mm² — that covers control wiring and motor leads up to about 8 AWG. The analog output is configurable as 4-20 mA or 0-10 V, so it can feed a remote SCADA or panel meter with motor current or torque signal.

Approvals and compliance documentation

No separate agency review needed for most panel builds. Accuracy Class 5 per IEC 61557-12 means the built-in current measurement is within 5 % — good enough for motor protection and energy monitoring without an external CT. The event list, error logbook, and trace function give you diagnostics for commissioning and fault finding without a laptop. Firmware updates are supported in the field — so if Siemens releases a new feature or a bug fix, you can flash it without swapping the hardware. The service factor is 1.15, meaning the soft starter can handle 115 % of rated current continuously — useful for motors running near full load in hot environments.

Frequently asked questions

What compliance documentation does Siemens provide for the 3RW5515-1HA04?

The unit also carries ATEX and IECEx certification for hazardous locations. RoHS and REACH declarations are standard with Siemens industrial products; the specific declaration can be requested at order time.

What is the 3RW5515-1HA04's ATEX certification?

ATEX is listed as Yes — the soft starter is certified for use in potentially explosive atmospheres. This covers the unit itself, not just an external enclosure, so it can be installed in Zone-classified areas without additional protection barriers.

How do I get current pricing and availability for the 3RW5515-1HA04?

We source this through independent industrial distribution. Submit an RFQ with your target quantity and delivery window; we'll confirm current pricing and lead time against your BOM. No stock-holding claim — availability is confirmed at quote time.

MPN
3RW5515-1HA04