Siemens 3RW5524-1HA14 — Soft Starters

Siemens 3RW5524-1HA14 Soft Starter, 200-480V, ATEX, Fieldbus

MPN3RW5524-1HA14
Active

Siemens SIRIUS 3RW5524-1HA14 soft starter, 200-480 V rated voltage, ATEX / IECEx certified, trip classes 10A/10E/20E/30E, PROFIBUS/Modbus/EtherNet/IP, screw terminals.

$1,159.00Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5524-1HA14 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW5524-1HA14 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)22 kW
Rated motor power at 230 V (40 °C)11 kW
Rated operational current at 40 °C81.4 A
Rated operational current at 50 °C72 A
Rated operational current at 60 °C62.7 A
Rated insulation voltage480 V
Minimum settable current (% of Ie)10 %; Relative to set Ie
Power loss during startup (50 °C)504 W
3RW5524-1HA14 — Control & Connection
ParameterValue
Control supply voltage typeAC
Main circuit terminal typebox terminal
Control circuit wire range, solid1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
Control circuit wire range, finely stranded (with ferrule)1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)10 %
Control supply voltage tolerance, AC 50 Hz (min.)-15 %
Control supply voltage tolerance, AC 60 Hz (max.)10 %
Control supply voltage tolerance, AC 60 Hz (min.)-15 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %
3RW5524-1HA14 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection) / When using the motor overload protection according to ATEX, an upstream contactor is required in inside-delta circuit.
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5524-1HA14 — Mechanical
ParameterValue
Height306 mm
Width185 mm
Depth203 mm
Weight5.5 kg
Mounting positionVertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°)
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5524-1HA14 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5524-1HA14 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 360 s
Ramp-Down Time Of Soft Starter0 ... 360 s
3RW5524-1HA14 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable125 ... 800 %
Starting Voltage [%]20 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

The Siemens 3RW5524-1HA14 is a SIRIUS soft starter for three-phase induction motors, rated for a supply voltage of 200 to 480 V. It carries ATEX and IECEx certification for use in potentially explosive atmospheres — that means the soft starter itself is approved for installation in Zone 2 or Zone 22 areas (equipment protection level Gc/Dc), so you can place it inside the hazardous boundary rather than forcing a remote panel. Trip class is configurable: CLASS 10A or 10E by default, with options for 20E or 30E per IEC 60947-4-2. The 10A setting clears a stall in 10 seconds at 7.2x rated current — standard for most conveyor and pump starts. Bumping to 30E gives you 30 seconds for high-inertia loads like centrifuges or large fans without nuisance tripping. Communication is multi-protocol out of the box: PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP are all listed. That saves a separate gateway card for plants running mixed-fieldbus lines. PROFIenergy is also supported when paired with the PROFINET High-Feature module, letting the drive coordinate energy-saving pauses during idle periods.

Panel fit and clearance

Dimensions: 306 mm high, 185 mm wide, 203 mm deep. Mounting is via screw terminals. Clearance requirements are asymmetrical — 100 mm above, 75 mm below, only 10 mm forward, 0 mm backward, and 5 mm to the side. That tight rear clearance means you can back it against a panel wall, but the 100 mm top gap is mandatory for heat plume rise; skimping there derates the unit.

Lifecycle and compliance posture

Compliance documentation is comprehensive: CE marking for European markets, UL and CSA approvals for North America, plus ATEX and IECEx for hazardous locations. Accuracy Class 5 per IEC 61557-12 applies to the integrated metering function — that means current and voltage measurement uncertainty stays within 5 % of reading, adequate for energy monitoring but not revenue-grade billing.

What the control features mean on the line

Built-in torque control, voltage ramp, pump ramp down, and breakaway pulse cover the common starting profiles. Voltage ramp is the standard for reducing inrush on conveyors; pump ramp down closes valves gradually to avoid water hammer. Breakaway pulse delivers a short high-torque burst to break a stuck load loose before ramping — useful for crushers or screw feeders that bind after a shutdown. Analog output is configurable as 4-20 mA or 0-10 V, defaulting to 4-20 mA. That lets you feed motor current, power, or temperature to a PLC analog card without a separate transducer. The error logbook, event list, trace function, and motor heating model are all on-board — no extra software license for basic fault analysis. Service factor of 1.15 means the soft starter can handle a motor nameplated at 115 % of its rated load without tripping — common in pump applications where the motor is oversized for the driven load. DC braking is included for quick stops on low-inertia loads, though it should not be used for frequent jogging as it heats the rotor.

Frequently asked questions

What hazardous-area approvals does it carry?

ATEX and IECEx certification are both listed. That qualifies it for installation in Zone 2 or Zone 22 explosive atmospheres (gas and dust), per the equipment protection level Gc/Dc.

What fieldbus protocols are supported?

PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP are all on-board. PROFIenergy is supported when paired with the PROFINET High-Feature communication module.

What are the mounting clearances?

100 mm above, 75 mm below, 10 mm forward, 0 mm backward, and 5 mm to the side. The 100 mm top clearance is mandatory for heat dissipation.

Does it include a built-in analog output?

Yes, a configurable analog output is standard — 4-20 mA by default, switchable to 0-10 V. It can transmit motor current, power, or temperature to a PLC analog input.