Position switch Metal enclosure 56 mm wide Device connection 3x (M20x 1.5) 1 NO/1 NC quick action contacts Rotary actuator right/left adjustable, Rod lever made of plastic 200 mm long

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3SE5122-0CH82 — Identification
ParameterValue
Product designationMechanical position switches
Product brand nameSIRIUS

Switching & Safety

3SE5122-0CH82 — Switching & Safety
ParameterValue
Positive opening functionNo
Auxiliary NO contacts1
Auxiliary NC contacts1
Circuit principlesnap-action contacts
Active principlemechanical
Safety-related switching contacts0
Suitable as safety switchNo
Switching contact designmechanical
Safety-related interface connectorwithout

Mechanical

3SE5122-0CH82 — Mechanical
ParameterValue
Actuating element designRod lever, plastic rod, length 200 mm
Standard-compliant actuator headEN 50041, design D
Switch head shaperoller
Repeat accuracy0.05 mm
Enclosure materialmetal
Switch head enclosure materialplastic
Mounting positionany
Fastening methodscrew fixing
Length281 mm
Width56 mm
Enclosure coatingcathodic dip coating
Housing design standardblock, wide

Environmental

3SE5122-0CH82 — Environmental
ParameterValue
IP protection ratingIP65/IP67
Operating temperature range-25 ... +85 °C
Storage temperature range-40 ... +90 °C
Shock resistance (IEC 60068-2-27)30g / 11 ms
Pollution degreeclass 3

Wiring

3SE5122-0CH82 — Wiring
ParameterValue
Electrical connection typescrew-type terminals
Interface connector designwithout
Conductor cross-section, finely stranded (with ferrule)1x (0.5 ... 1.5 mm²), 2x (0.5 ... 0.75 mm²)
Conductor cross-section, solid1x (0.5 ... 1.5 mm²), 2x (0.5 ... 0.75 mm²)
Cable entry type3x (M20 x 1.5)

Electrical

3SE5122-0CH82 — Electrical
ParameterValue
Rated insulation voltage400 V
Thermal current10 A
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage6 kV
Rated current at 24 V3 A
Rated current at 125 V0.55 A
DIAZED gG fuse link, continuous current6 A
C-characteristic MCB, continuous current1 A; for a short-circuit current smaller than 400 A
Quick DIAZED fuse link, continuous current10 A; for a short-circuit current smaller than 400 A

Specifications

3SE5122-0CH82 — Specifications
ParameterValue
Of The Supplied Switching Contacts3SE5000-0CA00
MPN
3SE5122-0CH82