Skip to main content
Siemens 3VA1010-2ED42-0AC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1010-2ED42-0AC0 SENTRON MCCB, 100 A, 4-Pole, TM21

MPN3VA1010-2ED42-0AC0

Siemens SENTRON 3VA1010-2ED42-0AC0, molded case circuit breaker, 4-pole, 100 A, TM210 trip unit, line protection, 52.5 kA at 240 V, IP40 front.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3VA1010-2ED42-0AC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1010-2ED42-0AC0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C96 A
Current at 60 °C94 A
Current at 65 °C92 A
Current at 70 °C90 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 690 V7.5 kA
3VA1010-2ED42-0AC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1010-2ED42-0AC0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1010-2ED42-0AC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts2
3VA1010-2ED42-0AC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1010-2ED42-0AC0 — Mechanical
ParameterValue
Height130 mm
Width101.6 mm
Depth70 mm

Product details

Breaking capacity hits 52.5 kA at 240 V and 32 kA at 415 V, which covers most industrial distribution panels stepping down from a 400 V feed. The 70 mm depth and 101.6 mm width fit standard MCCB mounting footprints in a switchboard or enclosure.

Ratings and selectivity

Rated continuous current Iu of 100 A holds flat through 50 °C, then derates to 96 A at 55 °C and 90 A at 70 °C — useful for a warm panel with limited airflow. The breaking capacity curve is steep: 52.5 kA at 240 V, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at 690 V. At 415 V, 32 kA gives solid headroom for a 25 kA prospective fault level in a typical IEC 60947-2 installation.

Mounts in a switchboard or enclosure on a standard MCCB footprint — 70 mm depth, 101.6 mm width, 130 mm height. The 2 auxiliary switches (HQ version) provide status feedback for a PLC or indication lamp; no communication module or voltage trigger built in.

Frequently asked questions

How do I get pricing and availability for 3VA1010-2ED42-0AC0?

Sourced and quoted to order against an RFQ through independent distribution. Current pricing and availability are confirmed at quote time — submit an RFQ for a firm quote.

What is the breaking capacity of 3VA1010-2ED42-0AC0 at 415 V?

32 kA at 415 V, with 52.5 kA at 240 V and 13.6 kA at 440 V.

Does 3VA1010-2ED42-0AC0 include an undervoltage release or ground fault monitoring?

No — it ships without an undervoltage release and without ground fault monitoring. The TM210 trip handles overload and short-circuit only.

MPN
3VA1010-2ED42-0AC0