Skip to main content
Siemens 3VA1010-2ED42-0AD0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1010-2ED42-0AD0 SENTRON MCCB, 4P, 100 A, 25 kA at

MPN3VA1010-2ED42-0AD0

Siemens SENTRON, 3VA1010-2ED42-0AD0, molded case circuit breaker (MCCB), 4-pole, 100 A (at 40-50 °C), breaking capacity 52.5 kA at 240 V, TM210 overcurrent release, line protection design.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3VA1010-2ED42-0AD0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10102ED420AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1010-2ED42-0AD0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C98 A
Current at 60 °C96 A
Current at 65 °C94 A
Current at 70 °C91 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.25 W
3VA1010-2ED42-0AD0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1010-2ED42-0AD0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1010-2ED42-0AD0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts3
3VA1010-2ED42-0AD0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1010-2ED42-0AD0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

Siemens SENTRON 3VA1010-2ED42-0AD0 — 4-Pole MCCB with TM210 Release

It carries a 4-pole design with no undervoltage release, no trip indicator, and no communication function — a straightforward thermal-magnetic breaker for conventional distribution panels. The overcurrent release is the TM210 type, a fixed thermal-magnetic trip unit. Rated continuous current holds at 100 A up to 50 °C ambient, then derates to 98 A at 55 °C, 96 A at 60 °C, 94 A at 65 °C, and 91 A at 70 °C — useful when the breaker sits inside a warm enclosure without forced cooling. Breaking capacity is specified at several voltages: 52.5 kA at 240 V, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at 500 V and 690 V. It accommodates up to three auxiliary switches of the HQ type (ordered separately).

Frequently asked questions

Where can I buy the 3VA1010-2ED42-0AD0 and how do I get a price?

Sourced to order through independent distribution. Submit an RFQ — availability and current pricing are confirmed at quote time. No stock figures or prices are published here.

What compliance documentation does the SENTRON series provide for this MCCB?

As a Siemens SENTRON molded case circuit breaker, the 3VA1010-2ED42-0AD0 is designed to meet applicable IEC/EN 60947-2 and UL 489 standards. RoHS and REACH declarations are typically available from the manufacturer's documentation portal.

Does the 3VA1010-2ED42-0AD0 have a trip indicator or undervoltage release?

No. The spec indicates no trip indicator and no undervoltage release. It is a basic thermal-magnetic MCCB for line protection without auxiliary trip accessories.

What is the depth of this MCCB?

Depth is 70 mm (2.76 in). Combined with a width of 101.6 mm (4 in) and height of 130 mm (5.12 in), it fits standard panel-mount cutouts for 4-pole MCCBs.

MPN
3VA1010-2ED42-0AD0