Siemens 3VA1080-3ED32-0AF0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1080-3ED32-0AF0 SENTRON MCCB, 80 A, 3-Pole, TM210

MPN3VA1080-3ED32-0AF0

Siemens SENTRON 3VA1080-3ED32-0AF0, molded case circuit breaker, 3-pole, 80 A (40 °C), TM210 thermal-magnetic release, line protection, 70 mm depth.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3VA1080-3ED32-0AF0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10803ED320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1080-3ED32-0AF0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C80 A
Current at 45 °C80 A
Current at 50 °C80 A
Current at 55 °C78 A
Current at 60 °C77 A
Current at 65 °C75 A
Current at 70 °C74 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.19.2 W
3VA1080-3ED32-0AF0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1080-3ED32-0AF0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1080-3ED32-0AF0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts2
3VA1080-3ED32-0AF0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1080-3ED32-0AF0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The TM210 thermal-magnetic release handles overloads and short-circuits without external control power.

Breaking capacity — what it means for fault duty

At 240 V it breaks 75.6 kA; at 415 V, 52.5 kA; at 440 V, 32 kA; and at 500 V and 690 V it holds at 7.5 kA. For a 480 V panel with a 50 kA available fault current, this breaker covers the high-fault end at 240 V but you need to check the 440 V figure (32 kA) against your actual fault study — a common gotcha when the transformer secondary is 480 V.

Panel fit and auxiliary switch

Dimensions are 130 mm tall, 76.2 mm wide (3 in), and 70 mm deep — a standard MCCB footprint that drops into most DIN-rail or panel-mount bases without re-drilling. Power loss is 19.2 W max — account for that in a sealed enclosure thermal calc.

Frequently asked questions

What is the breaking capacity of this MCCB at 415 V?

At 415 V the breaking capacity is 52.5 kA. This is the figure to use for most European 400 V distribution panels.