Siemens 3VA1216-5EF32-0CC0 SENTRON MCCB, 160 A, 3-Pole, 121

MPN3VA1216-5EF32-0CC0

Siemens SENTRON 3VA1216-5EF32-0CC0, molded case circuit breaker, 3-pole, 160 A, line protection, 121 kA at 415 V, with undervoltage release and 2 auxiliary switches HQ.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3VA1216-5EF32-0CC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA12165EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1216-5EF32-0CC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C156 A
Current at 60 °C151 A
Current at 65 °C147 A
Current at 70 °C142 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V30 kA
Breaking capacity at 690 V17 kA
Power loss, max.35.5 W
3VA1216-5EF32-0CC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1216-5EF32-0CC0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1216-5EF32-0CC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1216-5EF32-0CC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1216-5EF32-0CC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height158 mm
Width105 mm
Depth70 mm
Height (in)6.22 in
Width (in)4.13 in
Depth (in)2.76 in

Product details

It carries a continuous current of 160 A at 40 °C ambient, derating to 142 A at 70 °C, with a rated insulation voltage of 800 V.

The thermal derating curve is flat from 40 °C to 50 °C at 160 A, then drops linearly to 142 A at 70 °C.

No communication function is fitted, so remote trip or monitoring requires an external module.

The 3VA frame measures 105 mm wide × 158 mm high × 70 mm deep, which is the standard 3-pole MCCB footprint for this class. Maximum power dissipation is 35.5 W at rated load — account for that in enclosure thermal calculations, especially in a densely packed panel.

Frequently asked questions

What is the breaking capacity of 3VA1216-5EF32-0CC0 at 415 V?

The interrupting capacity is 121 kA at 415 V AC, with higher ratings at lower voltages (187 kA at 240 V) and lower at higher voltages (17 kA at 690 V).

What auxiliary switches and releases come with this MCCB?

It includes an undervoltage release (UVR) and two HQ auxiliary switches, providing trip-on-loss-of-voltage protection and status feedback without add-on modules.

Where can I buy 3VA1216-5EF32-0CC0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3VA1216-5EF32-0CC0