Siemens 3VA2040-6KP32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA2040-6KP32-0AA0 MCCB, 40 A, 3-Pole, 242 k

MPN3VA2040-6KP32-0AA0
Active

Siemens SENTRON 3VA series, molded case circuit breaker, 3VA2040-6KP32-0AA0, 40 A, 3-pole, 242 kA at 240 V, ETU850 trip unit, IP40 front.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2040-6KP32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2040-6KP32-0AA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3 kA
Power loss, max.2.2 W
3VA2040-6KP32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
Overcurrent protection functionLSI
Ground-fault monitoringWithout
3VA2040-6KP32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2040-6KP32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0
3VA2040-6KP32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2040-6KP32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2040-6KP32-0AA0 is a 3-pole molded case circuit breaker rated at 40 A continuous, with an ETU850 electronic trip unit. It's built for line protection in distribution panels and motor control centers where you need high interrupting capacity — 242 kA at 240 V and 187 kA at 415 V — so it handles fault currents at the main or sub-main level without cascading upstream.

At 690 V the breaker still clears 3 kA, which is enough for most industrial line-to-line faults in a 690 V system. The ETU850 trip unit supports adjustable overload and short-time pickup, so you can coordinate with downstream breakers and avoid nuisance trips.

The breaker measures 105 mm wide, 181 mm tall, and 86 mm deep — a standard 3-pole MCCB footprint for DIN-rail or screw-mount panels. The front face is IP40, so it's suited for enclosed switchboards.

MPN
3VA2040-6KP32-0AA0