Skip to main content
Siemens 3VA2140-0HM36-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2140-0HM36-0AA0 SENTRON MCCB, 40 A, 440 kA at 415

MPN3VA2140-0HM36-0AA0
Active

Siemens SENTRON 3VA2140-0HM36-0AA0, Molded Case Circuit Breaker, 40 A, 3-pole, ETU330, 440 kA at 415 V, 86 x 105 x 181 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2140-0HM36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2140-0HM36-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classE
Breaking capacity at 415 V440 kA
Breaking capacity at 690 V187 kA
Power loss, max.1.2 W
3VA2140-0HM36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU330
Overcurrent protection functionLIG
Ground-fault monitoringSummation current formation L-conductor
Grounding protection functionYes
3VA2140-0HM36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2140-0HM36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2140-0HM36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2140-0HM36-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens 3VA2140-0HM36-0AA0 is a 3-pole SENTRON molded case circuit breaker rated for 40 A continuous current, designed for line protection in distribution panels. Breaking capacity is 440 kA at 415 V and 187 kA at 690 V — that's high enough to handle most transformer-fed fault currents upstream of a sub-distribution board without cascading failure. The 40 A rating holds flat from 40 °C through 70 °C ambient, so no derating headache in a warm enclosure or near other heat sources. Dimensions are 86 mm deep, 105 mm wide, 181 mm tall — standard 3-pole MCCB footprint for a 160 A frame.

Integration — panel fit and wiring notes

The 86 mm depth leaves clearance for rear-access cable routing. The ETU330 trip unit is powered from the line-side current transformers, so no auxiliary supply needed. Ground-fault protection is built in (summation current formation on L-conductor), which saves adding a separate GFCI module downstream.

Frequently asked questions

Will 3VA2140-0HM36-0AA0 drop into a panel specified for 3VA2163-8HM32-0AA0?

No — the 3VA2163-8HM32-0AA0 is a larger frame rated for higher current. The 3VA2140-0HM36-0AA0 has a different mounting footprint and busbar spacing. Check the panel cutout dimensions before substituting.

MPN
3VA2140-0HM36-0AA0