Siemens SENTRON 3VA2 series, molded case circuit breaker, 3VA2140-0HM32-0AA0, 3-pole, 40 A continuous, ETU330 electronic trip unit, 440 kA at 415 V, 187 kA at 690 V.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2140-0HM32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2140-0HM32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classE
Breaking capacity at 415 V440 kA
Breaking capacity at 690 V187 kA
Power loss, max.1.2 W
3VA2140-0HM32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU330
Overcurrent protection functionLIG
Ground-fault monitoringSummation current formation L-conductor
Grounding protection functionYes
3VA2140-0HM32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2140-0HM32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2140-0HM32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2140-0HM32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Siemens 3VA2140-0HM32-0AA0 — 40 A SENTRON MCCB with ETU330 Trip Unit

The Siemens 3VA2140-0HM32-0AA0 is a 3-pole SENTRON molded case circuit breaker rated for 40 A continuous current, built around the ETU330 electronic trip unit. It's designed for line protection in distribution panels, with a 440 kA breaking capacity at 415 V and 187 kA at 690 V — enough to handle high-fault utility feeds without cascading upstream breakers. That means it catches phase-to-ground faults without a separate GFCI module — a space saver on the DIN rail.

At 86 mm deep, 105 mm wide, and 181 mm tall, this MCCB fits standard SENTRON 3VA2 panel cutouts. Power loss is 1.2 W maximum at rated load, so thermal rise inside a dense panel is minimal — no special derating needed for adjacent breakers in a standard 40 °C ambient.

Frequently asked questions

What is the breaking capacity of this MCCB at 415 V and 690 V?

It's rated for 440 kA at 415 V and 187 kA at 690 V, making it suitable for high-fault-current installations like utility mains or large transformer secondaries.

What trip unit does the 3VA2140-0HM32-0AA0 use?

It uses the ETU330 electronic trip unit with adjustable settings and integral ground-fault monitoring via summation current formation on the L-conductor.

Where can I buy the 3VA2140-0HM32-0AA0 and get current pricing?

This part is sourced to order through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time.

Will the 3VA2140-0HM32-0AA0 drop into a panel designed for 3VA2140-8JQ32-0AA0?

Both are 3VA2 frame breakers with the same 86 mm depth, 105 mm width, and 181 mm height, so the mechanical footprint is identical. The difference is in the trip unit and accessories — verify the wiring scheme matches your application.

MPN
3VA2140-0HM32-0AA0