Skip to main content
Siemens 3VA2140-5HL32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2140-5HL32-0AA0 SENTRON MCCB, 40 A, 3-Pole, ETU32

MPN3VA2140-5HL32-0AA0
Active

Siemens SENTRON 3VA2 series, molded case circuit breaker, 3-pole, 40 A, ETU320 electronic trip unit, line protection, 187 kA at 240 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2140-5HL32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2140-5HL32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.1.6 W
3VA2140-5HL32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VA2140-5HL32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2140-5HL32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2140-5HL32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2140-5HL32-0AA0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What the ratings mean for your panel

The Siemens 3VA2140-5HL32-0AA0 is a SENTRON molded case circuit breaker rated for 40 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling, which simplifies panel layout in warm enclosures. Its interrupting capacity hits 187 kA at 240 V AC and 121 kA at 415 V AC, so it handles high-fault service-entrance or sub-distribution positions without cascading upstream breakers. The ETU320 electronic trip unit provides adjustable overload and short-circuit protection curves, suited for line protection in motor branch circuits or feeder applications where coordination selectivity matters. At 86 mm deep, 105 mm wide, and 181 mm tall, it fits standard SENTRON 3VA2 panel cutouts and busbar arrangements — a direct swap for any 3-pole 40 A frame in the series.

Integration notes for the panel builder

Front face carries IP40 protection — suitable for enclosed panel mounting where no washdown or dust ingress is expected. Rated insulation voltage Ui is 800 V AC; operational voltage is 690 V AC. No undervoltage release, no shunt trip, no ground-fault monitoring, and no communication module on this variant — it is a straight line-protection breaker with the ETU320 trip unit only. Power loss at rated current is 1.6 W maximum — negligible for thermal budgeting inside a crowded panel.

Frequently asked questions

What is 3VA2140-5HL32-0AA0's listed depth?

The depth is 86 mm (3.39 in), with a width of 105 mm (4.13 in) and height of 181 mm (7.13 in).

MPN
3VA2140-5HL32-0AA0