Siemens 3VA2140-5KP32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2140-5KP32-0AA0 SENTRON MCCB, 40 A, 187 kA at 240

MPN3VA2140-5KP32-0AA0
Active

Siemens SENTRON 3VA2140-5KP32-0AA0, 3-pole molded case circuit breaker, 40 A rated current, ETU850 electronic trip unit, 187 kA interrupting capacity at 240 VAC.

$495.30Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2140-5KP32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2140-5KP32-0AA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V76 kA
Breaking capacity at 690 V3.8 kA
Power loss, max.1.6 W
3VA2140-5KP32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
Overcurrent protection functionLSI
Ground-fault monitoringWithout
3VA2140-5KP32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2140-5KP32-0AA0 — Accessories & Functions
ParameterValue
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0
3VA2140-5KP32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2140-5KP32-0AA0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.1 in
Width (in)4.1 in
Depth (in)3.4 in

Product details

The Siemens 3VA2140-5KP32-0AA0 is a 3-pole SENTRON molded case circuit breaker (MCCB) configured for line protection, carrying a full-rated 40 A continuously from 40 °C through 70 °C — no derating needed across the typical panel ambient range. That 40 A is the same at 40 °C, 45 °C, 50 °C, 55 °C, 60 °C, 65 °C, and 70 °C, so the breaker holds its rating in a warm enclosure without a temperature correction factor. The interrupting capacity tells the selectivity story: 187 kA at 240 V, 121 kA at 415 V and 440 V, 76 kA at 500 V, and 3.8 kA at 690 V. At typical 480Y/277 V distribution, the 121 kA SCCR gives ample headroom for a high-fault service entrance or downstream coordination with smaller branch breakers. The ETU850 electronic trip unit (adjustable Ii from 60 A to 480 A, Ig min 0.5 s) enables precise long-time and short-time pickup settings — critical for selective coordination studies required by NEC 240.87 and 240.91.

Communication function is built in (no external module required), and the neutral conductor is upgradeable or retrofittable — useful for 4-wire systems where you add the neutral pole later.

Frequently asked questions

What is the interrupting capacity of 3VA2140-5KP32-0AA0 at 240 V?

187 kA at 240 V, dropping to 121 kA at 415 V and 440 V, 76 kA at 500 V, and 3.8 kA at 690 V.

What trip unit does 3VA2140-5KP32-0AA0 use?

The ETU850 electronic overcurrent release, with adjustable short-time pickup (Ii) from 60 A to 480 A and a minimum ground-fault response time of 0.5 s.

Where can I buy 3VA2140-5KP32-0AA0 and how is it quoted?

This part is sourced to order through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time.

Will 3VA2140-5KP32-0AA0 drop into a panel specified for 3VA2140-8JQ42-0AA0?

Both are 3-pole SENTRON MCCBs in the same 181 x 105 x 86 mm frame, so the mechanical footprint is identical. The difference is the trip unit and accessories — verify the ETU850 settings match your coordination study before swapping.