Skip to main content
Siemens 3VA2163-8HN42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-8HN42-0AA0 SENTRON MCCB, 63 A, 4-Pole, ETU35

MPN3VA2163-8HN42-0AA0
Active

Siemens SENTRON 3VA2163-8HN42-0AA0, molded case circuit breaker, 4-pole, 63 A rated continuous current, ETU350 electronic trip unit, 440 kA interrupting at 240 V.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2163-8HN42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2163-8HN42-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classL
Breaking capacity at 240 V440 kA
Breaking capacity at 415 V330 kA
Breaking capacity at 440 V330 kA
Breaking capacity at 500 V220 kA
Breaking capacity at 690 V52.5 kA
Power loss, max.3.1 W
3VA2163-8HN42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2163-8HN42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-8HN42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2163-8HN42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-8HN42-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

What this MCCB is and what the ratings mean for fit

The Siemens SENTRON 3VA2163-8HN42-0AA0 is a 4-pole molded case circuit breaker (MCCB) designed for line protection in distribution panels. Its continuous current rating holds at 63 A across the full ambient range from 40 °C to 70 °C — no derating needed up to that temperature, which simplifies panel layout in warm enclosures. The interrupting ratings tell you where this breaker can safely clear a fault: 440 kA at 240 V, 330 kA at 415 V and 440 V, 220 kA at 500 V, and 52.5 kA at 690 V. That 440 kA at 240 V is the headline number — it handles the high available fault current you get close to a large transformer or a utility service entrance. The 52.5 kA at 690 V still covers most industrial 690 V distribution without needing a current-limiting fuse upstream. The ETU350 electronic trip unit gives you adjustable overload and short-circuit protection curves, which is what you want for coordinating with downstream breakers in a selective system. Insulation voltage is rated 800 V, so the breaker is suitable for 690 V line-to-line systems with margin.

Physical fit and panel integration

Dimensions are 140 mm wide, 181 mm high, and 86 mm deep. The 140 mm width for a 4-pole frame is standard for SENTRON 3VA2 breakers — it will drop into the same mounting footprint as other 3VA2 4-pole units. Front protection is IP40, meaning tools and fingers stay out, but it is not sealed against washdown; keep it inside the enclosure.

Frequently asked questions

Who supplies 3VA2163-8HN42-0AA0 and how is it quoted for volume purchases?

This part is sourced through independent distribution and quoted to order against an RFQ. Volume pricing and availability are confirmed at quote time.

Will 3VA2163-8HN42-0AA0 drop into a panel that was specified around 3VA2163-8HM32-0AA0 without rewiring?

Both are 4-pole SENTRON 3VA2 breakers sharing the same frame dimensions (140 mm wide, 181 mm high, 86 mm deep), so the mechanical footprint is identical. The 8HN42-0AA0 carries the ETU350 trip unit; the 8HM32-0AA0 uses a different trip unit — verify that the protection settings match your coordination study before swapping.

What is 3VA2163-8HN42-0AA0's listed depth (86 mm) on this component line?

The depth is 86 mm (3.39 in).

What is 3VA2163-8HN42-0AA0's listed width (140 mm) on this component line?

The width is 140 mm (5.51 in).

What compliance documentation does this brand provide for 3VA2163-8HN42-0AA0 (RoHS, REACH, UL, IEC)?

As a Siemens SENTRON MCCB, the 3VA2163-8HN42-0AA0 is designed to meet IEC 60947-2 and UL 489 standards; RoHS and REACH declarations are available from Siemens on request.

MPN
3VA2163-8HN42-0AA0