Siemens 3VA4112-6ED34-1AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA4112-6ED34-1AA0 SENTRON MCCB, 125 A, 65 kA at 480

MPN3VA4112-6ED34-1AA0
Active

Siemens SENTRON 3VA4112-6ED34-1AA0, 3-pole molded-case circuit breaker, 125 A, 65 kA at 480 V AC, TM210 thermal-magnetic trip unit, system protection design.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA4112-6ED34-1AA0 — Identification
ParameterValue
Product designationMolded-case circuit breaker
Brand / rangeSENTRON
3VA4112-6ED34-1AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Current at 40 °C125 A
Current at 45 °C125 A
Current at 50 °C125 A
Current at 55 °C122 A
Current at 60 °C120 A
Current at 65 °C117 A
Current at 70 °C115 A
Switching capacity classH
Breaking capacity at 240 V100 kA
Power loss, max.29.1 W
3VA4112-6ED34-1AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA4112-6ED34-1AA0 — Construction & Connection
ParameterValue
Main circuit connection typeInfeed side: Low tab
Main circuit connector arrangementoutput side: circular conductor connection
Protection class (IP), frontIP40
3VA4112-6ED34-1AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA4112-6ED34-1AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA4112-6ED34-1AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.15 000
Height129.4 mm
Width76.2 mm
Depth75.1 mm
Height (in)5.09 in
Width (in)3 in
Depth (in)2.96 in

Product details

The Siemens 3VA4112-6ED34-1AA0 is a 3-pole SENTRON molded-case circuit breaker (MCCB) rated 125 A continuous at 40 °C through 50 °C, derating to 115 A at 70 °C. Interrupting capacity is 100 kA at 240 V AC, 65 kA at 480 V AC, and 25 kA at 600 Y/347 V AC. These SCCR figures cover most industrial distribution panels up to 480 V — the 65 kA rating at 480 V is the one that typically governs the bus bracing and upstream transformer impedance. At 600 V corner-grounded delta or wye systems, the 25 kA limit is the binding constraint.

Maximum power loss is 29.1 W, which is moderate for a 125 A frame. Panel ventilation and adjacent device spacing should follow the manufacturer's derating guidelines for enclosures above 40 °C.

Dimensions are 76.2 mm wide, 129.4 mm high, and 75.1 mm deep — a standard 3-pole MCCB footprint that fits most DIN-rail or panel-mount bases in the SENTRON range. The TM210 thermal-magnetic trip unit provides fixed thermal and magnetic settings — no interchangeable rating plugs or electronic adjustments. This simplifies ordering but means the breaker must be sized at the BOM stage for the exact load current; field re-rating is not possible without replacing the entire device.

Frequently asked questions

What is the interrupting capacity of this MCCB at 480 V?

65 kA at 480 V AC, and 100 kA at 240 V AC. At 600 Y/347 V the rating drops to 25 kA.

Where can I buy 3VA4112-6ED34-1AA0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit a request for a firm quote.

What is the closest functional second-source to 3VA4112-6ED34-1AA0?

The peer MPNs 5SQ2370-2YA05, 5SQ2370-2YA04, and 5SQ2370-2YA01 are listed as related alternatives. Verify the trip curve, interrupting rating, and physical footprint against your panel design before substituting — the 3VA series uses the TM210 thermal-magnetic trip, while the 5SQ series may differ in trip characteristics or accessory compatibility.