Skip to main content
Siemens 3VA4150-6ED34-3AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA4150-6ED34-3AA0 Circuit Breaker, 65 kA @ 480 V, 5

MPN3VA4150-6ED34-3AA0
Active

Siemens 3VA4 UL Frame 125, circuit breaker, breaking capacity class H 65 kA @ 480 V, 3-pole, TM210 line protection, FTFM, In=50 A, Ir=50 A fixed, Ii=10 x In.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3VA4150-6ED34-3AA0 — Specifications
ParameterValue
Group codeP360
Product group5385
Product classC: products manufactured / produced to order, which cannot be reused or re-utilized or be returned against credit.
SeriesOrdering Data Overview
Export control regulationsAL : N / ECCN : EAR99
Compliance with the substance restrictions according to RoHS directiveSince: 13-05-19

Product details

Panel integration and trip coordination

The Siemens 3VA4150-6ED34-3AA0 is a 3-pole UL Frame 125 molded-case circuit breaker rated for 65 kA interrupting capacity at 480 V — class H breaking capacity, sized for high-fault industrial distribution panels where upstream transformer capacity drives available fault current above 25 kA. The TM210 thermal-magnetic trip unit is factory-set with overload protection Ir=50 A (fixed, not adjustable) and instantaneous short-circuit pickup Ii=10 x In (500 A). This fixed-trip configuration suits dedicated motor branch circuits or fixed-load feeders where the OCPD rating matches the load nameplate — no field adjustment needed, no risk of mis-calibration. FTFM (Fixed Thermal, Fixed Magnetic) means the trip curve is locked at the factory; the breaker ships as a single-purpose device. For a panel OEM wiring a 50 A compressor or pump circuit, this eliminates the possibility of an operator dialing the Ir up past the conductor ampacity.

RoHS compliance confirmed since May 2019. The declaration is on file for downstream user obligations under EU REACH. Export control classification: AL N / ECCN EAR99 — no special licensing required for commercial shipments outside embargoed destinations.

Sourcing and order posture

Product class C: manufactured/produced to order, not a stocked off-the-shelf item. This means the breaker is built against a confirmed order and cannot be returned for credit once produced. Packaged singly, dimensions 472 x 396 x 213 mm — sized for individual carton shipment rather than bulk pallet. The packaging quantity of 1 piece matches the made-to-order production flow.

Frequently asked questions

What compliance documentation is available for the 3VA4150-6ED34-3AA0?

RoHS compliance since May 2019 and REACH Article 33 disclosure for lead content are documented. Export control is AL N / ECCN EAR99.

Where can I buy the 3VA4150-6ED34-3AA0 and what is the lead time?

This made-to-order product is sourced and quoted against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the group code and product group for this breaker?

Group Code P360, Product Group 5385 — these are internal Siemens classification codes used for ordering data overview and catalog navigation.

MPN
3VA4150-6ED34-3AA0