3VM1150-4ED32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VM1150-4ED32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Current at 40 °C50 A
Current at 45 °C50 A
Current at 50 °C50 A
Current at 55 °C49 A
Current at 60 °C48 A
Current at 65 °C46 A
Current at 70 °C45 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V76 kA
Breaking capacity at 440 V53 kA
Breaking capacity at 500 V12 kA
Power loss, max.15 W
3VM1150-4ED32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VM1150-4ED32-0AA0 — Construction & Connection
ParameterValue
Main circuit connector arrangementFront connection
Protection class (IP), frontIP40
3VM1150-4ED32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VM1150-4ED32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VM1150-4ED32-0AA0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VM1150-4ED32-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated 50 A continuous at 40 °C through 50 °C, with a TM210 thermal-magnetic trip unit. The interrupting ratings climb to 121 kA at 240 V AC and 76 kA at 415 V AC — numbers that tell you this breaker can clear high fault currents on a 240 V or 400 V distribution bus without upstream coordination issues. The TM210 release means the thermal pickup is fixed at 50 A; there is no adjustable long-time delay or electronic trip unit, so this breaker is a straight 50 A feeder or branch protector. The 15 W maximum power loss matters for panel heat buildup — if you are packing several breakers in a small enclosure, that loss adds up and may force derating or ventilation.