Skip to main content
Siemens 4EU3022-7AA00-0AA0 — Line/Load Reactors

Siemens 4EU3022-7AA00-0AA0 Commutating Choke, 200A Max, 690V

MPN4EU3022-7AA00-0AA0

Siemens 4EU3022-7AA00-0AA0 commutating choke for converter, 3-phase, 690V AC, 180A rated (200A max), 0.24mH, 4% voltage drop, IP00, Class H insulation.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

4EU3022-7AA00-0AA0 specifications
ParameterValue
Type of voltageAC
Type of electrical connection for main current circuitflat connector
Operating voltage rated value690V
Relative inductive drop in voltage on the measurement level current, voltage and frequency4%
Power loss [W] of the coil210W
Power loss [W] of the iron core132W
Operating frequency rated value50Hz
Phase number3
Ambient temperature rated value40°C
Depth0.211m
Width0.3m
Height0.269m
Thermal class acc. to IEC 60085H
Rated value180A
At DC rated value245A
Protection class IPIP00
Inductivity rated value0.00024H

Product details

The Siemens 4EU3022-7AA00-0AA0 is a three-phase commutating choke for converter input circuits. It limits current rise and harmonics on the AC line. Rated 180 A continuous with a 200 A maximum, it handles 690 V AC at 50 Hz and delivers 0.00024 H inductance with a 4% voltage drop. This is an open-frame (IP00) component — no enclosure, so it mounts inside a cabinet or panel where the environment is clean and dry. The flat-type terminals accept busbar or cable lugs for the main circuit connection. Thermal class H per IEC 60085 means the winding insulation withstands 180 °C hot-spot temperature, which suits the high ambient (40 °C rated) and the combined copper and iron losses of 342 W total.

The 180 A rated current (200 A max) is the continuous thermal current (Ith) at 40 °C ambient — this is the current the choke can carry indefinitely without exceeding the Class H temperature rise. For a 690 V drive system, that translates to roughly a 200–250 kW motor load depending on the drive topology and overload profile. The 0.00024 H inductance with a 4% voltage drop at 50 Hz limits di/dt and reduces harmonic distortion. A 4% impedance is a common choice for general-purpose drive applications. The 342 W total power loss (210 W copper + 132 W iron) is heat that must be managed inside the enclosure. At 180 A, that's about 1.9 W per amp — factor this into your panel ventilation or forced-air cooling calculation.

The design complies with EN 61558-2-20, the standard for chokes and reactors for power supplies and converters. This is the relevant IEC safety standard for this component class.

MPN
4EU3022-7AA00-0AA0