5SM3746-5 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SM3746-5 — Identification
ParameterValue
Product designationRCCB
Product design / constructionSelective
5SM3746-5 — Mechanical
ParameterValue
Mounting positionany
Width in modular units4
Maximum45 °C
Minimum-25 °C
Width72 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SM3746-5 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens SENTRON 5SM3746-5 is a 4-pole selective residual current circuit breaker (RCCB) rated 63 A at 400 V AC, 50/60 Hz. The Type B residual-current detection means it trips on AC, pulsating DC, and smooth DC fault currents — the full spectrum you get from variable-speed drives, UPS systems, or photovoltaic inverters. The 500 mA rated tripping fault current is higher than a standard 30 mA RCD, so it's sized for selective coordination: it lets downstream 30 mA devices clear a ground fault first, only tripping this upstream unit if the fault persists or exceeds its threshold.

IP20 with conductors connected, so it's intended for enclosed panels only, not washdown or outdoor exposure.

Thermal derating — the real-world current

Above that, it steps down: 60.48 A at 50 °C, 57.96 A at 55 °C, 55.44 A at 60 °C, 52.92 A at 65 °C, and 50.4 A at 70 °C.

Frequently asked questions

What is the 5SM3746-5 rated current and voltage?

63 A at 400 V AC, 50/60 Hz, 4-pole. The 63 A holds up to 45 °C ambient; derate above that per the thermal table.

What is the difference between the 5SM3746-5 and the 5SL4363-7?

The 5SL4363-7 is a standard (non-selective) RCCB, while the 5SM3746-5 is selective (time-delayed). The selective version coordinates with downstream 30 mA RCDs so only the faulted branch trips first. Both are 4-pole, 63 A, Type B, but the 5SM3746-5 carries a higher short-circuit rating (10 kA vs 0.8 kA per EN 60898) and a different tripping characteristic. They are not drop-in substitutes without checking the coordination study.

Where can I buy the 5SM3746-5 and get a price?