Siemens SENTRON 5SU1324-7FA40 RCBO, 2P, C-curve, 40 A, 10 kA

MPN5SU1324-7FA40
Active

Siemens SENTRON 5SU1324-7FA40 RCBO, 2-pole instantaneous, C-curve, 40 A at 30 °C, 10 kA (EN 60898) / 15 kA (IEC 60947-2), 230/240 V AC, 50 Hz, IP20, halogen-free.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU1324-7FA40 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU1324-7FA40 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SU1324-7FA40 — Mechanical
ParameterValue
Mounting positionany
Width in modular units3
Maximum75 °C
Minimum-40 °C
Width54 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU1324-7FA40 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU1324-7FA40 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

Rated parameters and breaking capacity

Rated at 40 A at 30 °C with a rated voltage of 230/240 V AC at 50 Hz, it provides overcurrent and earth-fault protection in a single module. The breaking capacity is 10 kA per EN 60898 and 15 kA per IEC 60947-2 — the higher IEC figure matters when the device is installed in an industrial distribution board where fault levels may exceed the domestic 10 kA threshold. Supply can enter from either top or bottom, and the mounting position is unrestricted. IP20 applies only when the distribution board is installed with conductors connected.

Thermal derating and environmental range

Rated current is 40 A at 30 °C, derating to 29.2 A at 70 °C. The full derating curve is documented: 37.6 A at 40 °C, 36.4 A at 45 °C, 34.8 A at 50 °C, 32.4 A at 55 °C and 60 °C, and 30.8 A at 65 °C. For a panel that sees elevated internal temperatures — typical in a crowded enclosure or near a heat source — use the 40 °C or 50 °C column to size the circuit, not the 30 °C headline figure.

Insulation voltage (Ui) is 264 V, surge voltage resistance is 4 000 V. The minimum test voltage is 195 V.

Frequently asked questions

Who supplies 5SU1324-7FA40 and how is it quoted for volume purchases?

The part is sourced through independent distribution channels and quoted to order against an RFQ. Availability and current pricing are confirmed at the time of quotation.

What is the breaking capacity of 5SU1324-7FA40?

10 kA per EN 60898 and 15 kA per IEC 60947-2. The higher IEC rating applies when the device is used in industrial distribution boards.