Siemens 5SU9326-1CN63 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9326-1CN63 SENTRON RCBO, 63A C-Curve, 30mA, 2-Pol

MPN5SU9326-1CN63

Siemens SENTRON RCBO, 2-pole, 63 A rated, C-curve, 30 mA residual current, 6 kA breaking capacity, order code 5SU9326-1CN63.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SU9326-1CN63 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU9326-1CN63 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SU9326-1CN63 — Mechanical
ParameterValue
Mounting positionany
Width in modular units4
Maximum75 °C
Minimum-40 °C
Width72 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU9326-1CN63 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU9326-1CN63 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

Siemens SENTRON 5SU9326-1CN63 — RCBO, 63 A, 30 mA, C-Curve

It carries a 63 A rated current at AC with a C tripping characteristic, a 30 mA residual current sensitivity, and a 6 kA breaking capacity per EN 60898 and IEC 60947-2. The 30 mA sensitivity means it protects against fatal electric shock from direct contact — the standard threshold for socket-outlet circuits in residential and commercial installations. The C-curve (5–10× In) handles inrush from motor loads, fluorescent lighting banks, and small transformers without nuisance tripping, while the 6 kA short-circuit capacity clears faults up to that level in a 230/400 V distribution board.

Thermal Derating and Installation Constraints

At 40 °C the continuous current must be derated to 58.6 A; at 45 °C to 56.1 A; at 50 °C to 54.8 A; and at 55 °C to 53.6 A. This derating curve governs the real load an RCBO can carry in a closed distribution board — an unventilated enclosure at 45 °C knocks nearly 7 A off the headline figure. Depth is 77 mm, installation depth 70 mm.

Regulatory and Compliance Profile

Overvoltage category III (distribution level), pollution degree 2. The insulation voltage is rated 264 V. It is halogen-free and silicon-free. Touch protection is provided. Energy limitation class 3. The residual current type is AC (sinusoidal AC fault currents only). The product designation per IEC 81346-2 and DIN EN 61346-2 is F (protective device).

Frequently asked questions

What are the key ratings of the 5SU9326-1CN63?

63 A rated current at AC, C tripping characteristic, 30 mA residual current sensitivity, 6 kA breaking capacity per EN 60898 and IEC 60947-2, 2 poles, 4 modular width units.

Where can I buy the 5SU9326-1CN63?

The 5SU9326-1CN63 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at the time of quote — submit an RFQ for a firm response.

What is the difference between the 5SU9326-1CN63 and the 5SU9326-1CN16?

The 5SU9326-1CN16 is the 16 A variant of the same 2-pole, 30 mA, C-curve RCBO family. Both share the same 4-MU footprint, 6 kA breaking capacity, and SENTRON design. The 63 A unit (5SU9326-1CN63) is for higher-current final circuits; the 16 A unit serves lighting and general socket circuits. Panel cutouts and wiring are identical — swap without rewiring if the load current is within the lower rating.