Skip to main content
Siemens 5SV1316-7GV10 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV1316-7GV10 SENTRON RCBO, 10A, 30mA, Type A, 6kA

MPN5SV1316-7GV10
Active

Siemens SENTRON RCBO, 2-pole (1P+N), 10 A rated, 30 mA residual current, Type A, C-curve, 6 kA / 10 kA breaking capacity, 18 mm wide, active production.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Electrical Ratings

5SV1316-7GV10 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII

Identification

5SV1316-7GV10 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous

Mechanical

5SV1316-7GV10 — Mechanical
ParameterValue
Mounting positionany
Width in modular units1
Maximum75 °C
Minimum-40 °C
Width18 mm
Height90 mm
Depth77 mm
Installation depth70 mm

Environmental

5SV1316-7GV10 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Electrical

5SV1316-7GV10 — Electrical
ParameterValue
Tripping Characteristic ClassC
Operational current / at AC / rated value10 A

Product details

What it is and what the ratings mean for fit

The Siemens SENTRON 5SV1316-7GV10 is a 2-pole (1P+N) RCBO — a combined residual-current circuit breaker with overcurrent protection in a single 18 mm modular-width unit. The 10 A rated operational current and C-curve tripping characteristic mean it protects final circuits with moderate inrush, like lighting or small motor loads, while the 30 mA rated residual fault current provides additional protection against electric shock. The Type A designation means it detects both sinusoidal AC residual currents and pulsed DC residual currents — important for circuits with rectifiers or switching power supplies. Breaking capacity is rated at 6 kA per EN 60898 and 10 kA per IEC 60947-2. The higher IEC figure applies when the RCBO is used in industrial distribution where the prospective short-circuit current may exceed the domestic standard. The 1P+N configuration switches the line conductor and disconnects the neutral, which is standard for single-phase final circuits in TN or TT systems.

Panel integration and mounting

At 18 mm wide — one modular unit — it snaps onto standard DIN rail. The 77 mm depth and 70 mm installation depth fit standard distribution boards with connected conductors. Mounting position is any, and the supply can enter from top or bottom. The IP20 rating applies when installed in a distribution board with connected conductors — normal for enclosed panel use.

Environmental and compliance

Rated for ambient temperatures from -40 °C to 75 °C and up to 95% humidity. Halogen-free and silicon-free construction. Overvoltage category III and pollution degree 2 suit fixed-installation distribution. The neutral conductor is switched, and touch protection is provided.

Frequently asked questions

What is the breaking capacity of 5SV1316-7GV10?

It is rated 6 kA per EN 60898 and 10 kA per IEC 60947-2.

What is the residual current rating and type?

30 mA, Type A — detects both AC and pulsed DC residual currents.

How wide is 5SV1316-7GV10?

18 mm, which is one modular unit on standard DIN rail.

Where can I buy 5SV1316-7GV10 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

MPN