Skip to main content
Siemens 5SY8404-8 — 4-Pole MCB (DIN Rail)

Siemens SENTRON 5SY8404-8 MCB, D Curve, 4 A, 4-Pole, 50 kA

MPN5SY8404-8
Active

Siemens SENTRON miniature circuit breaker, 5SY8404-8, D characteristic, 4-pole, 4 A (45 °C), 400 V AC, 50 kA IEC 60947-2, 4 MW wide, quick-assembly system.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY8404-8 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY8404-8 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC400 V
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Voltage typeAC
5SY8404-8 — Protection
ParameterValue
Tripping characteristic (trip curve)D
Rated breaking capacity, per IEC 60947-250 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingNo
Touch protectionYes
5SY8404-8 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY8404-8 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C

Product details

The Siemens SENTRON 5SY8404-8 is a 4-pole miniature circuit breaker with a D tripping characteristic, rated 4 A at 45 °C ambient on a 400 V AC system. On DC circuits it's rated 15 kA per IEC 60947-2, and under UL 1077 / CSA C22.2 No. 235 it carries 5 kA at AC — relevant if the panel ships to North America under those standards. The 4-pole version (4P) switches all three phases plus the neutral — common in three-phase distribution where the neutral needs overcurrent protection or is switched for isolation. Mounting position is any; the quick-assembly system clips onto the standard DIN rail, occupying 4 modular width units (about 72 mm).

Temperature derating and environmental limits

The 5SY8404-8 is rated 4 A at 45 °C, but the current must be derated as ambient rises: 3.9 A at 50 °C, 3.8 A at 55 °C. Above that, the surrounding temperature influence curve caps at 95% relative humidity up to 55 °C, then 55% RH up to 70 °C, and 35% RH up to 75 °C maximum. The minimum storage/operating temperature is -40 °C, covering cold-start conditions in outdoor or unheated installations.

Mechanical and vibration withstand

Tested to IEC 60068-2-6 for vibration resistance: ±1 mm displacement at 5 to 25 Hz, and 50 m/s² acceleration at 25 to 150 Hz. That covers most industrial panel vibration environments — motor starters, conveyor lines, compressor skids — without the breaker nuisance-tripping or loosening on the DIN rail. Overvoltage category III and degree of pollution 3 confirm it's rated for fixed installations inside the distribution board, not for the final outlet.

Frequently asked questions

What is the breaking capacity of the 5SY8404-8?

50 kA per IEC 60947-2 at 400 V AC, 15 kA per IEC 60947-2 at DC, and 5 kA per UL 1077 / CSA C22.2 No. 235 at AC. The 50 kA figure tells you it can handle high fault currents typical of strong utility supplies without needing an upstream current-limiting device.

What does the D tripping characteristic mean for this breaker?

The D curve (10–20× In) is designed for loads with high inrush currents — motor starters, transformers, welding equipment — where a B or C curve would trip on startup. At 4 A rated, the magnetic trip picks up between 40 A and 80 A.

Will the 5SY8404-8 fit in a panel designed for a 4-pole MCB from the same SENTRON family?

Yes. The 5SY8404-8 uses the standard SENTRON quick-assembly system, mounts on DIN rail in any position, and occupies 4 modular width units (72 mm wide, 70 mm installation depth). It fits the same panel cutouts and busbar systems as other SENTRON 4-pole MCBs.

What compliance documentation is available for the 5SY8404-8?

The breaker carries IEC 60947-2 and UL 1077 / CSA C22.2 No. 235 ratings, and is designated per IEC 81346-2 and DIN EN 61346-2. It is halogen-free and silicon-free, supporting RoHS and REACH compliance requirements. Specific declarations are available through the manufacturer's documentation portal.

Where can I buy the 5SY8404-8 and how is it quoted?

The 5SY8404-8 is sourced through independent industrial-automation distribution. Pricing and availability are confirmed at quote time against an RFQ — no online stock or price is published. Submit an RFQ for current lead time and volume pricing.

MPN
5SY8404-8