Specifications

6AG1332-5HB01-2AB0 — Outputs
ParameterValue
Number of analog outputs2
Output range: -10 V to +10 VYes
Output range: 0 to 10 VYes
Output range: 1 V to 5 VYes
Output range: 0 to 20 mAYes
Output range: 4 to 20 mAYes
Output range: -20 mA to +20 mAYes
Load resistance, current outputs, max.500 Ω
Load resistance, voltage outputs, min.1 kΩ
Current output, no-load voltage, max.18 V
Voltage output, short-circuit current, max.25 mA
Voltage output, short-circuit protectionYes
Inductive load, current outputs, max.10 mH
Capacitive load, voltage outputs, max.1 µF
Cable length, shielded, max.200 m
6AG1332-5HB01-2AB0 — Performance
ParameterValue
Resolution (incl. sign, with overrange), max.12 bit; ±10 V, ±20 mA, 4 mA to 20 mA, 1 V to 5 V: 11 bit + sign; 0 V to 10 V, 0 mA to 20 mA: 12 bit
Error, voltage output (rel. to output range)0.4 %
Error, current output (rel. to output range)0.5 %
Conversion time (per channel)0.8 ms
Settling time, resistive load0.2 ms
Settling time, inductive load0.5 ms; 0.5 ms (1 mH); 3.3 ms (10 mH)
Settling time, capacitive load3.3 ms
6AG1332-5HB01-2AB0 — Power
ParameterValue
Rated value (DC)24 V; A power supply according to EN 50155 shall be used for railway applications
Power loss (typ.)3 W
Current consumption from backplane bus (5 V DC), max.60 mA
Current consumption from load voltage L+ (no load), max.135 mA
Reverse polarity protectionYes
6AG1332-5HB01-2AB0 — Diagnostics
ParameterValue
Diagnostics functionYes; Parameterizable
Diagnostic interrupt/alarmYes; Parameterizable
6AG1332-5HB01-2AB0 — Isolation
ParameterValue
Isolation: channels to backplane busYes
Isolation: between channelsNo
Isolation: channels to load voltage L+Yes
Isolation test voltage500 V DC
6AG1332-5HB01-2AB0 — Environmental
ParameterValue
Temperature, max.70 °C
Temperature, min.-40 °C
Installation altitude, max.5 000 m
6AG1332-5HB01-2AB0 — Mechanical
ParameterValue
Front connector required20-pin
Width40 mm
Height125 mm
Depth120 mm

Product details

The 6AG1332-5HB01-2AB0: Two output channels share a common conversion time of 0.8 ms per channel. The module accepts voltage (0–10 V, 1–5 V, ±10 V) and current (0–20 mA, 4–20 mA, ±20 mA) outputs, covering nearly any loop or actuator interface on a 24 V DC control bus. On the current outputs the load can go up to 500 Ω; voltage outputs need a minimum 1 kΩ load. Diagnostics are fully parameterizable — the module can raise a group error (red SF LED) and read back fault details over the backplane. Isolation between channels and the bus is tested at 500 V DC, and reverse polarity on the supply is blocked onboard. For inductive loads, the settling time stretches to 0.5 ms (1 mH) or 3.3 ms (10 mH); resistive and capacitive loads settle in 0.2 ms and 3.3 ms respectively.

Beyond EN 50155, the module carries UL (File E239877), CE, KC, EAC, and RCM marks. The 24 V DC supply must come from a source that meets EN 50155 for railway installations, but the module itself is rated for general industrial approvals as well.

This module is in current lifecycle stage. The 20-pin front connector is required but sold separately.

Frequently asked questions

What temperature range does the module support?

It is rated for -40 °C to 70 °C operating range, making it suitable for railway and cold-climate installations.

What compliance certifications does it carry?

The module holds EN 50155 (railway), UL (File E239877), CE, KC, EAC, and RCM approvals.

MPN
6AG1332-5HB01-2AB0