Specifications

6EP1332-2BA20 — Electrical – Output
ParameterValue
Rated output voltage (DC)24 V
Rated current2.5 A
Rated current range0 ... 3 A; 3 A up to +45°C; +60 ... +70 °C: Derating 3%/K
Output power at rated voltage/current (typ.)10 W
Output voltage characteristicControlled, isolated DC voltage
Output 1 rated voltage (DC)24 V
Output voltage adjustableYes
6EP1332-2BA20 — Electrical – Input & Efficiency
ParameterValue
Supplied active power (typ.)60 W
Efficiency85 %
Power supply network type1-phase AC
Maximum3.5 mA
6EP1332-2BA20 — Protection & Isolation
ParameterValue
Ingress protection (IP) ratingIP20
Protection classClass I
Short-circuit proof outputYes
Short-circuit protection designConstant current characteristic
Galvanic isolation input/outputYes
Galvanic isolation (SELV / standards)Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178
6EP1332-2BA20 — Connections
ParameterValue
Electrical connection typescrew-type terminals
Input terminalsL, N, PE: 1 screw terminal each for 0.5 ... 2.5 mm² single-core/finely stranded
Output terminals+, -: 2 screw terminals each for 0.5 ... 2.5 mm²
6EP1332-2BA20 — Mechanical
ParameterValue
Mounting methodSnaps onto DIN rail EN 60715 35x7.5/15
Enclosure width32.5 mm
Enclosure height125 mm
Enclosure depth120 mm
Side-by-side mountableYes
Mounting clearance, left0 mm
Mounting clearance, right0 mm
Mounting clearance, top50 mm
Mounting clearance, bottom50 mm
6EP1332-2BA20 — Environmental
ParameterValue
Operating temperature range-25 ... +70 °C; with natural convection
Storage temperature range-40 ... +85 °C
Transport temperature range-40 ... +85 °C
Climatic class (IEC 60721)Climate class 3K3, 5 … 95% no condensation
Current limitation of inrush current at 25 °C maximum33 A
6EP1332-2BA20 — Approvals & EMC
ParameterValue
CE markingYes
UL approvalYes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cCSAus (CSA C22.2 No. 60950-1, UL 60950-1)
CSA approvalYes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cCSAus (CSA C22.2 No. 60950-1, UL 60950-1)
NEC Class 2No
ATEX approvalNo
IECEx approvalNo
UL HazLoc approvalNo
cCSAus Class I Div 2 (hazardous loc.)No
EAC approvalYes
Shipbuilding approvalBV, DNV GL
EMC – emission standardEN 55022 Class B
EMC – immunity standardEN 61000-6-2
6EP1332-2BA20 — Reliability & Features
ParameterValue
MTBF at 40 °C1 804 044 h
Equipment bridgingYes
Status indicators / displayGreen LED for 24 V OK
6EP1332-2BA20 — Electrical
ParameterValue
Adjustable Output Voltage22.8 ... 28 V

Product details

The Siemens 6EP1332-2BA20 is a SITOP PSU100C power supply delivering a rated output of 2.5 A at 24 V DC, with automatic range selection on the AC input side covering 85–132 V and 170–264 V at 47–63 Hz. The output is safety extra-low voltage (SELV) per EN 60950-1 and EN 50178, so it can directly power PLCs, sensors, and 24 V DC control circuits without additional isolation.

The rated current of 2.5 A holds up to +45 °C ambient; above that, derate 3 % per K up to +70 °C. At 40 °C the MTBF is over 1.8 million hours, which translates to low expected failure rates in continuous-duty applications like conveyor controls or pump stations. The recommended upstream protection is a miniature circuit breaker rated 3 A, characteristic C. The internal fuse is a T 3.15 A / 250 V type, not user-accessible, so the MCB is your primary overcurrent device. Input inrush is limited to 3.5 A maximum, typically 0.4 A, which avoids nuisance tripping of the feeder breaker during power-up.

This unit carries cULus listing under UL 508 and CSA C22.2 No. 107.1 (File E197259), plus cCSAus to CSA C22.2 No. 60950-1 and UL 60950-1. CE and EAC marks are present. It is not ATEX or IECEx rated, and not NEC Class 2. DNV GL marine approval is confirmed, so it suits shipboard or offshore installations where classification society certification is required.

Frequently asked questions

Where can I buy 6EP1332-2BA20 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability.

What compliance documentation does this brand provide for 6EP1332-2BA20?

The unit carries cULus (UL 508, CSA C22.2 No. 107.1), cCSAus (CSA C22.2 No. 60950-1, UL 60950-1), CE, EAC, and DNV GL approvals. It is not ATEX, IECEx, or NEC Class 2.

What is 6EP1332-2BA20's listed top (50 mm) on this component line?

The top dimension is 50 mm, which is the height of the unit when mounted on DIN rail.

What is 6EP1332-2BA20's listed ATEX (No) on this component line?

ATEX certification is not applicable; this unit is not rated for explosive atmospheres.