Skip to main content
Siemens 6EP3124-0TA00-0AY0 — DIN Rail Power Supplies

Siemens 6EP3124-0TA00-0AY0 Power Supply, 15 A, 24 VDC, DIN R

MPN6EP3124-0TA00-0AY0
Active

Siemens SITOP PSU8200, 6EP3124-0TA00-0AY0, 24 V DC / 15 A, DIN rail mount, 91% efficiency, IP20.

$244.98Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

6EP3124-0TA00-0AY0 — Electrical – Output
ParameterValue
Rated output voltage (DC)12 V
Rated current15 A
Rated current range0 ... 15 A; +60 ... +70 °C: Derating 2%/K
Output power at rated voltage/current (typ.)21 W
Output voltage characteristicControlled, isolated DC voltage
Output 1 rated voltage (DC)12 V
Output voltage adjustableYes
6EP3124-0TA00-0AY0 — Electrical – Input & Efficiency
ParameterValue
Supplied active power (typ.)200 W
Efficiency91 %
Power supply network typeDC voltage
Maximum10 ms
6EP3124-0TA00-0AY0 — Protection & Isolation
ParameterValue
Ingress protection (IP) ratingIP20
Protection classClass III
Short-circuit proof outputYes
Short-circuit protection designElectronic shutdown, automatic restart
Galvanic isolation input/outputYes
Galvanic isolation (SELV / standards)Safety extra low output voltage Vout according to EN 60950-1
6EP3124-0TA00-0AY0 — Connections
ParameterValue
Electrical connection typescrew-type terminals
Input terminalsL, N, FE: 1 screw terminal each for 0.5 ... 2.5 mm² single-core/finely stranded
Output terminals+, -: 2 screw terminals each for 0.5 ... 2.5 mm²
6EP3124-0TA00-0AY0 — Mechanical
ParameterValue
Mounting methodSnaps onto DIN rail EN 60715 35x7.5/15
Enclosure width42 mm
Enclosure height125 mm
Enclosure depth120 mm
Side-by-side mountableYes
Mounting clearance, left0 mm
Mounting clearance, right0 mm
Mounting clearance, top50 mm
Mounting clearance, bottom50 mm
6EP3124-0TA00-0AY0 — Environmental
ParameterValue
Operating temperature range-25 ... +70 °C; with natural convection
Storage temperature range-40 ... +85 °C
Transport temperature range-40 ... +85 °C
Climatic class (IEC 60721)Climate class 3K3, 5 … 95% no condensation
Current limitation of inrush current at 25 °C maximum15 A
6EP3124-0TA00-0AY0 — Approvals & EMC
ParameterValue
CE markingYes
UL approvalYes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259
CSA approvalYes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259
NEC Class 2No
ATEX approvalNo
IECEx approvalNo
UL HazLoc approvalNo
cCSAus Class I Div 2 (hazardous loc.)No
EAC approvalYes
Shipbuilding approvalABS, DNV GL
EMC – emission standardEN 61000-6-3
EMC – immunity standardEN 61000-6-2
6EP3124-0TA00-0AY0 — Reliability & Features
ParameterValue
MTBF at 40 °C1 411 273 h
Equipment bridgingYes
Status indicators / displayGreen LED for 12 V OK
6EP3124-0TA00-0AY0 — Electrical
ParameterValue
Adjustable Output Voltage12 ... 15.5 V

Product details

The Siemens 6EP3124-0TA00-0AY0 is a 24 V DC switched-mode power supply rated for 15 A continuous, with a typical output of 16 A. It delivers 91% efficiency at rated load, which keeps heat dissipation low in a crowded cabinet. The input accepts 14 to 32 V DC, so it works on nominal 24 V battery-backed or rectified DC buses without a separate input module. Mounting is standard DIN rail per EN 60715 (35×7.5/15). Clearance of 50 mm above and below the unit is required for natural convection cooling; the side gaps can be zero. The output is galvanically isolated and SELV-rated per EN 60950-1, so it is safe for powering PLCs, I/O racks, sensors, and other 24 V control loads in industrial and commercial panels. The unit is also approved for shipboard use (ABS, DNV GL), which extends its suitability to marine and offshore installations.

Ratings That Drive the Selection

Between +60 °C and +70 °C ambient, the output must be reduced by 2% per Kelvin. At +65 °C, for example, the usable current drops to about 13.5 A. If the panel runs hot, size up or add forced air. Startup is guaranteed from 18 V DC, with derated operation possible down to 14 V DC. This is useful for battery-backed systems where the bus voltage sags under load. The inrush current is limited to an I²t of 0.6 A²·s, which prevents nuisance tripping of upstream breakers. The recommended upstream protection is a 16 A miniature circuit breaker, characteristic B or C. The unit itself has an internal non-accessible 25 A fuse with a breaking capacity of 300 A, so it can handle a hard output short without cascading.

Approvals include cULus (UL 508, CSA C22.2 No. 107.1), CE, EAC, and DNV GL. The UL file number is E197259. No ATEX or IECEx certification — this is not a hazardous-location power supply. For a standard control panel or marine installation, the existing approvals cover the regulatory scope.

Terminal and Wiring Notes

Output terminals (+, -) are also screw terminals, same wire range. A separate signaling contact terminal block is provided for remote monitoring. All terminals are sized for standard panel wiring; no special tools needed. The unit can be bridged with a buffer module if ride-through during line dips is required. That is an accessory, not included, but the capability is built into the design.

Frequently asked questions

What clearance is needed around the unit for cooling?

50 mm above and 50 mm below the enclosure for natural convection. Side clearance can be 0 mm. Depth of the enclosure is 120 mm.

MPN
6EP3124-0TA00-0AY0