What the ratings tell you about fit
The 6ES7194-2MH10-0AA0: The thermal range of -40 to 80 °C covers both freezer and hot cabinet use. Halogen-free and silicone-free construction matters for clean-room or off-shore specs where outgassing can't be tolerated. The continuous bending radius is 100 mm; for one-off bends you can go to 20 mm. That 1 million bending cycle rating at 4 m/s and 4 m/s² acceleration puts it into cable-carrier duty – this is not a fixed-wiring patch cord but a flex cable for moving machine parts. Shielding is aluminum-clad foil plus a tin-plated copper braid – the combination handles both high-frequency radiated noise and low-frequency magnetic fields. Termination is through pre-molded M8 connectors, 4-pole, with a 180° cable outlet. No field wiring required.