Skip to main content
Siemens 6GT2801-4BA10-0AX2 — RFID & Auto-ID

Siemens 6GT2801-4BA10-0AX2 SIMATIC RF350R Reader, 13.56 MHz,

MPN6GT2801-4BA10-0AX2
Active

Siemens SIMATIC RF300, reader RF350R (GEN2), RS422 interface (3964R), without antenna, IP65, -25 to +70 °C, 75 x 75 x 41 mm, ATEX (Zone 3G/3D) and IECEx (Gc/Dc) for Zone 2/22.

$482.60Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

6GT2801-4BA10-0AX2 — RF / Air interface
ParameterValue
Operating frequency (rated)13.56 MHz
Supported RF protocolsRF300 specific, ISO 15693, ISO 18000-3, ISO 14443
Compatible transponders / systemsRF300, ISO 15693 and MOBY E transponder, for connecting to communication modules, EX: II 3 G Ex ec [ic] IIB T4 Gc, II 3 D Ex tc [ic IIB Gc] IIIC T80 °C Dc
Read/write range, max.140 mm; Range is dependent on transponder type: observe http://support.automation.siemens.com/WW/view/en/67384964
Air-interface data rate, max.106 kbit/s
Multitag capableNo
6GT2801-4BA10-0AX2 — Performance
ParameterValue
Read time per byte (typ.)0.13 ms
Write time per byte (typ.)0.13 ms
MTBF260 a
6GT2801-4BA10-0AX2 — Communication / Electrical
ParameterValue
Communication interfacesRS422
Voltage range (DC)20.4 ... 28.8 V
Rated value (DC)24 V
Current at 24 V (typ.)0.06 A
Status indicators (LEDs)5-color LED
6GT2801-4BA10-0AX2 — Mechanical
ParameterValue
Mounting / fastening method2 x M5 screws
Width75 mm
Height41 mm
Depth75 mm
MaterialPA 12
ColorTi gray
6GT2801-4BA10-0AX2 — Environmental
ParameterValue
Degree of protection (IP)IP64
Operating temperature range-25 ... +70 °C
Storage temperature range-40 ... +85 °C
Transport temperature range-40 ... +85 °C
Shock acceleration500 m/s²
Vibration acceleration200 m/s²
Shock resistance standardEN 60721-3-7 Class 7 M2
6GT2801-4BA10-0AX2 — Approvals
ParameterValue
IECEx certifiedYes

Product details

RFID reader for Zone 2/22 environments

The Siemens 6GT2801-4BA10-0AX2 is a SIMATIC RF300 RFID reader (RF350R GEN2) operating at 13.56 MHz with an RS422 interface using the 3964R protocol. It is designed for industrial identification in environments requiring ATEX Zone 3G/3D and IECEx Zone 2/22 certification, making it suitable for petrochemical and process areas where explosive atmospheres may be present. The IP64 enclosure means the reader body resists dust ingress and water splashes from any direction — adequate for washdown areas but not for continuous submersion. The housing is PA 12 (polyamide), silicon-free, and rated for a -25 to +70 °C operating range.

Read/write performance and antenna integration

Typical read and write access per byte is 0.13 ms, with a maximum transfer rate of 106 kbit/s over the air interface. The reader supports RF300-specific, ISO 15693, ISO 18000-3, and ISO 14443 protocols. It is not multitag-capable — each read cycle handles one transponder at a time. One external antenna connects via an M8, 4-pin connector; a fixed 3 m antenna cable is supplied. The RS422 communication interface uses an M12, 8-pin connector, with a maximum cable length of 1000 m. Mounting uses two M5 screws into the 75 x 75 x 41 mm footprint.

The reader is specified for use with RF300, ISO 15693, and MOBY E transponders.

Frequently asked questions

What is the MTBF of this reader?

The listed MTBF is 260 a (years), reflecting a design reliability suitable for continuous-duty industrial RFID applications.

What certifications does this reader carry?

It carries IECEx certification with marking EX: II 3 G Ex ec [ic] IIB T4 Gc, II 3 D Ex tc [ic IIB Gc] IIIC T80 °C Dc, making it approved for Zone 2/22 hazardous areas. It also meets ATEX requirements for Zone 3G/3D.

MPN