Skip to main content
Siemens 6SL3056-4AA32-3AV0 — AC Drives (VFD)

Siemens 6SL3056-4AA32-3AV0 Ammeter for SINAMICS V50, 0-230 A

MPN6SL3056-4AA32-3AV0
Active

Siemens SINAMICS V50 ammeter, 6SL3056-4AA32-3AV0, range 0-230 A, input 0-20 mA, made-to-order engineering product class D, active lifecycle.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

6SL3056-4AA32-3AV0 — Identification
ParameterValue
Product familyOrdering Data Overview
6SL3056-4AA32-3AV0 — Other specifications
ParameterValue
Group codeR220
Product group4923
Product classD: products made to order / customer's specifications, requiring engineering services, which cannot be re-used or utilized (design to customer)
Export control regulationsAL : N / ECCN : N

Product details

The Siemens 6SL3056-4AA32-3AV0 is a panel-mount ammeter purpose-built for the SINAMICS V50 drive family. It reads 0-230 A on the scale, driven by a standard 0-20 mA analog input signal — the loop you'd pull from a current transformer or drive analog output. That 0-20 mA input is the key fit detail: if your V50 or control card outputs 4-20 mA, you'll need a scaling resistor or a different meter; this one expects the full zero-based span.

Active and mature per the Siemens lifecycle tracker. REACH compliance is declared on the current candidate list — documentation available with the order.

Mounts in the standard SINAMICS V50 operator panel cutout. The 0-20 mA input loop is passive — the meter draws its signal from the drive's analog output or an external transducer. Verify the loop power source: if the V50 analog output is active (sourcing), wire directly; if it's passive (sinking), you'll need an external 24 VDC supply in series. The scale is fixed at 0-230 A, so the drive's current scaling parameter (p2002 in SINAMICS) should match that full-scale value for a direct read.

Frequently asked questions

What is the input signal range for this ammeter?

The input is 0-20 mA analog, scaled to a 0-230 A display range. It is not a 4-20 mA device — the zero-based span means it reads zero at 0 mA, not 4 mA.

Where can I buy 6SL3056-4AA32-3AV0 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Because it is a made-to-order class D product, availability and current pricing are confirmed at quote time — not a stocked shelf item.

What compliance documentation does Siemens provide for this ammeter?

REACH compliance is declared per the current candidate list (Article 33 duty to inform). Export controls are AL: N / ECCN: N. RoHS and UL documentation are not listed in the available spec record — request these at quote time if required for your compliance gate.

MPN
6SL3056-4AA32-3AV0