Skip to main content
Siemens 6SL3220-1YH62-0CB0 — AC Drives (VFD)

Siemens 6SL3220-1YH62-0CB0 SINAMICS G120X VFD, 450 kW

MPN6SL3220-1YH62-0CB0
Active

Siemens SINAMICS G120X infrastructure converter, 6SL3220-1YH62-0CB0, 450 kW, 3AC 500-690 V, IP20, Size FSH, with integrated MODBUS RTU, BACnet MS/TP, USS.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

6SL3220-1YH62-0CB0 — Identification
ParameterValue
Product familySINAMICS G120X infrastructure converters for HVAC/Water/Wastewater

Other specifications

6SL3220-1YH62-0CB0 — Other specifications
ParameterValue
Group codeR220
Product group4R53
Product classC: products manufactured / produced to order, which cannot be reused or re-utilized or be returned against credit.
Export control regulationsAL : N / ECCN : EAR99H
Compliance with the substance restrictions according to RoHS directiveSince: 11-03-20

Product details

450 kW overload profile for pump and fan duty

The 6SL3220-1YH62-0CB0 is a SINAMICS G120X infrastructure converter rated 450 kW with a 135% overload for 3 seconds, 110% for 60 seconds, and 100% for 240 seconds — a profile matched to centrifugal pump and fan starting torque where the peak demand is brief and the continuous load stays near the nameplate. It accepts 3-phase 500-690 V AC +10/-20% at 47-63 Hz, covering the common 575 V and 690 V industrial grids in North America and Europe without an external transformer.

Fieldbus integration for building automation

The drive ships with integrated MODBUS RTU, BACnet MS/TP, and USS protocols on the standard communication port — no option module needed for connection to a BAS controller or a water/wastewater SCADA system. No IO expansion or operator panel is included in the base unit; the control terminals and fieldbus interface handle start/stop, speed reference, and status feedback for remote operation.

Panel mounting and cooling in Size FSH

The FSH frame size with IP20 / UL open type protection requires mounting inside a ventilated enclosure — the drive relies on forced-air cooling from its internal fans, so the cabinet must allow free airflow through the heatsink fins and maintain ambient temperature between 0 and 45 °C.

Compliance and export documentation

RoHS compliant since March 2020, with a REACH Article 33 declaration for lead content above 0.1% w/w — the lead CAS-No. 7439-92-1 is present in certain component alloys and must be declared in the supply chain documentation. Export Control Classification is AL:N / ECCN:EAR99H, meaning no special export license is required for most destinations under US and EU regulations.

MPN