Skip to main content
Siemens 6SL3220-2YE56-1CP0 — AC Drives (VFD)

Siemens 6SL3220-2YE56-1CP0 SINAMICS G120X VFD, 315 kW

MPN6SL3220-2YE56-1CP0
Active

Siemens SINAMICS G120X infrastructure converter, 6SL3220-2YE56-1CP0, 315 kW, 380-480 VAC, 3-phase, IP20, PROFIBUS DP, Size FSH.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

6SL3220-2YE56-1CP0 — Identification
ParameterValue
Product familySINAMICS G120X infrastructure converters for HVAC/Water/Wastewater
6SL3220-2YE56-1CP0 — Other specifications
ParameterValue
Group codeR220
Product group4R53
Product classC: products manufactured / produced to order, which cannot be reused or re-utilized or be returned against credit.
Export control regulationsAL : N / ECCN : EAR99H
Compliance with the substance restrictions according to RoHS directiveSince: 11-03-20

Product details

315 kW HVAC drive with 135% overload and PROFIBUS DP

The 6SL3220-2YE56-1CP0 is a SINAMICS G120X infrastructure converter rated 315 kW at 380-480 VAC, with a 135% overload capability for 3 seconds, 110% for 60 seconds, and 100% for 240 seconds — the overload profile matches pump and fan starting duty where the inertia is low but the breakaway torque needs a short burst. Built for HVAC, water, and wastewater applications, it integrates a Category C3 RFI suppression filter for the 3-phase 380-480 V +10/-20% grid at 47-63 Hz, and ships with a Basic Operator Panel and IO expansion module plus onboard PROFIBUS DP fieldbus. The drive is classified as Product class C — manufactured to order, not a stocked shelf item — so lead time and pricing are confirmed per RFQ against the BOM quantity.

Panel integration and fieldbus fit

The packaging dimensions (800 x 1870 x 600 mm) give a sense of the crate size for logistics planning. PROFIBUS DP is integrated on the control board, so no separate communication module is needed for plants running a PROFIBUS backbone. The Basic Operator Panel (BOP) provides local parameter access and fault readout without a laptop.

Lifecycle and compliance — active, RoHS, REACH

RoHS compliant since 11-03-20, with a REACH Article 33 declaration for lead (CAS 7439-92-1) above 0.1% w/w. Export control classification is AL N / ECCN EAR99H — no special license required for most industrial destinations.

MPN
6SL3220-2YE56-1CP0