Specifications

6SL3220-2YE58-0CB0 — Identification
ParameterValue
Product familySINAMICS G120X infrastructure converters for HVAC/Water/Wastewater
6SL3220-2YE58-0CB0 — Other specifications
ParameterValue
Group codeR220
Product group4R53
Product classC: products manufactured / produced to order, which cannot be reused or re-utilized or be returned against credit.
Export control regulationsAL : N / ECCN : EAR99H
Compliance with the substance restrictions according to RoHS directiveSince: 11-03-20

Product details

Active production — still a current catalog item

The 6SL3220-2YE58-0CB0: Product class C means it is manufactured to order, not held as a stocked shelf item.

355 kW overload profile and what it means for motor sizing

Rated 355 kW with a 135% overload for 3 seconds, 110% for 60 seconds, and 100% for 240 seconds. That overload profile is typical for HVAC fan and pump loads where transient torque demand is brief — the drive handles starting inertia without oversizing the continuous rating. Input range is 3AC 380-480 V +10/-20%, 47-63 Hz. The RFI suppression filter is category C3, which meets conducted emission limits for industrial environments (second environment per EN 61800-3). In a residential or light-commercial first-environment installation, an external EMC filter may be needed.

Fieldbus and I/O — MODBUS RTU, BACnet MS/TP, USS

Integrated fieldbus options are MODBUS RTU, BACnet MS/TP, and USS. No IO expansion module is included — the Basic Operator Panel (BOP) is fitted for local parameter access. For BACnet integration in building management systems, the MS/TP port communicates at baud rates up to 76.8 kbps. Size FSH enclosure, IP20 / UL open type. Mounting in a panel requires clearance for the top cable entry and the integrated RFI filter — the packaging dimensions (800 x 1870 x 600 mm) give a sense of the shipping crate, not the drive footprint itself.

Compliance documentation — RoHS, REACH, export control

RoHS compliant since 11-03-20. REACH Article 33 disclosure: lead (CAS 7439-92-1) above 0.1% w/w in certain components — this triggers the duty to inform downstream users under EU REACH. Export control classification is AL: N / ECCN: EAR99H, meaning no special license required for most destinations.