315 kW at 690 V — overload profile for pump and fan loads
The 6SL3220-2YH56-1CF0: This SINAMICS G120X drive delivers 315 kW rated power with an overload capability of 135% for 3 seconds, 110% for 60 seconds, and 100% for 240 seconds — a profile matched to centrifugal pump and fan starting torque requirements where peak demand is brief and sustained overload is rare. Input supply is 3-phase 500 to 690 VAC +10/-20% at 47 to 63 Hz, covering the common 575 V and 690 V industrial grids in North America and Europe without an external transformer.
Fieldbus and I/O — PROFINET PN and Ethernet IP onboard
A Basic Operator Panel (BOP) and IO expansion are included as standard. The RFI suppression filter is category C3, suitable for industrial environments where the drive is connected to a dedicated supply transformer — not for residential or public low-voltage networks.
Active production, made-to-order — plan the lead time
Packaging dimensions are 800 x 1870 x 600 mm — the Size FSH enclosure is a floor-mount cabinet, not a wall-mount panel. Plan for rigging and floor space in the electrical room.
Compliance and export — RoHS, REACH, EAR99
RoHS compliant since March 2020. REACH Article 33 declares lead (CAS 7439-92-1) above 0.1% w/w — this is typical for power semiconductors and solder joints; the declaration is for the EU supply chain, not a functional restriction. Export Control Classification is AL: N / ECCN: EAR99H — no special license required for most destinations, but the H suffix indicates the drive contains encryption (PROFINET/Ethernet IP) and may trigger an annual self-classification report under US EAR.