Skip to main content
Siemens 3RK1300-0BS01-1AA4

Siemens 3RK1300-0BS01-1AA4 Reversing Starter, 0.14-0.2A, IP6

MPN 3RK1300-0BS01-1AA4

Siemens EM 300 RS reversing starter, 3RK1300-0BS01-1AA4, electromechanical, setting range 0.14-0.2A, AC-3 0.06kW/400V, IP65, PROFIBUS DP, with integrated brake contact.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RK1300-0BS01-1AA4 specifications
ParameterValue
IP ratingIP65
Temp operating max55 °C
Temp operating min0 °C
Depth134 mm
Width140 mm
Height270 mm

Product details

The Siemens 3RK1300-0BS01-1AA4 is an electromechanical reversing starter from the EM 300 RS family, designed for the ET 200X distributed I/O system. It combines motor starting, reversing, and overload protection in a single IP65-rated enclosure — no separate contactor-plus-overload assembly needed. Rated for AC-3 duty at 0.06 kW / 400 V, with a setting range of 0.14 to 0.2 A via a bimetal overload relay. That 0.2 A full-scale value sets the maximum continuous motor current the starter can protect — size the motor so its FLA falls within this window. Built-in PROFIBUS DP communication means this starter talks directly to the PLC without a separate gateway module — the bus address and diagnostics come through the ET 200X backplane. The integrated motor brake output (DC 500 V / 1 A) handles internally supplied brakes, saving an external brake relay.

Deployment context — where this lives

IP65 protection means the 3RK1300-0BS01-1AA4 is built for machine-mount or washdown zones — no separate control cabinet required. It bolts directly to the machine frame, and the 9-pole motor feeder and 9-pole power connection (tab terminals) keep field wiring clean. Operating voltage is 400 … 500 V AC, three-phase, with an ambient temperature range of 0 … 55 °C. The maximum short-circuit breaking capacity (Icu) at 400 V is 50 A — coordinate upstream protection (circuit-breakers, per the design) so fault energy stays within that limit. Dimensions: 134 mm deep × 140 mm wide × 270 mm high. That footprint fits within a standard ET 200X string — plan for the 140 mm width when laying out adjacent modules.

MPN
3RK1300-0BS01-1AA4