Skip to main content
Siemens 3RW4422-1BC35

Siemens 3RW4422-1BC35 SIRIUS Soft Starter, 50 A at 40 °C

MPN 3RW4422-1BC35

Siemens SIRIUS 3RW4422-1BC35 soft starter, 50 A at 40 °C, 690 V insulation voltage, 50/60 Hz, integrated bypass contactor, screw-type terminals.

$2,600.96 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW4422-1BC35 specifications
ParameterValue
Mountingscrew fixing
Depth270 mm
Width170 mm
Height192 mm

Product details

Current rating and thermal derating

The 3RW4422-1BC35: The 8 % minimum load setting means the soft starter can regulate starting torque down to very light-load applications like small pumps or fans without overshoot on the ramp. Adjustable current limitation lets you cap inrush below the 50 A rating for installations where the upstream breaker coordination demands a tighter peak.

Bypass topology and inside-delta wiring

Integrated bypass contactor means the thyristors are shorted out once the motor reaches full speed — no continuous semiconductor losses, so the enclosure heat load is just the bypass contactor's holding power. Inside-delta circuit support lets you wire the soft starter in the delta leg of a six-lead motor, reducing the current through the thyristors to 58 % of line current — useful for retrofitting into existing delta-wound motors without re-cabling the main circuit.

Mounting and panel integration

Dimensions 192 mm high, 170 mm wide, 270 mm deep — screw fixing with 100 mm clearance above, 75 mm below, and 5 mm at the sides for airflow. Mounting position allows vertical surface with ±90° rotation and ±22.5° tilt front-to-back — useful for tight enclosures where the backplane isn't perfectly plumb.

Protection and environmental ratings

Motor overload protection and intrinsic device protection are both integrated — no separate overload relay needed for the soft starter itself, though the motor still needs its own thermal model or PTC input. Pollution degree 3 per IEC 60947-4-2 means it tolerates conductive dust and occasional condensation — suitable for industrial environments without sealed cabinets. Storage temperature -25 to +80 °C, operation up to 60 °C — the storage range covers most warehouse conditions; the 60 °C operating ceiling matches the derating curve's top end.

MPN
3RW4422-1BC35