Siemens 3RW5075-6TB05

Siemens 3RW5075-6TB05 Soft Starter, 160 A, 200-600 V, ATEX

MPN 3RW5075-6TB05
Active

Siemens 3RW5075-6TB05 SIRIUS soft starter, 160 A minimum, 200-600 V rated voltage, ATEX, IECEx, UL, CSA, CE, Trip Class 10A/10E/20E, PROFIBUS, PROFINET, Modbus RTU/TCP, EtherNet/IP, 282 mm depth, 160 mm width, 230 mm height.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW5075-6TB05 specifications
ParameterValue
Mountingscrew fixing
Depth282 mm
Width160 mm
Height230 mm
Trip classCLASS 10 A / 10E (preset) / 20E; acc. to IEC 60947-4-2
Service factor1
Digital output version2 normally-open contacts (NO) / 1 changeover contact (CO)

Product details

160 A minimum — the motor size floor

The 3RW5075-6TB05: The 160 A minimum rating sets the smallest motor this soft starter can handle. For a 400 V line, that's roughly an 90 kW motor at full load; at 230 V, about 45 kW. If your BOM motor is smaller, this unit is oversized and you'll lose the soft-start benefit — the current threshold won't engage properly. Rated voltage spans 200 to 600 V, covering 208 V North American, 400 V European, and 480/600 V industrial lines in one order code. No voltage-tap selection needed.

Trip Class selection for motor protection

Trip Class 10A, 10E, or 20E per IEC 60947-4-2 — the preset is 10A/10E, which clears a locked-rotor condition in 10 seconds at 7.2× FLA. The class is field-selectable via the HMI or parameter set.

ATEX and IECEx — hazardous-area motor starting

ATEX and IECEx certified — this soft starter can control motors in Zone 1 or Zone 2 gas atmospheres and Zone 21 or Zone 22 dust atmospheres when installed in the appropriate enclosure. The certification covers the soft starter itself, not the motor; the motor must also carry its own ATEX rating for the zone. UL and CSA approvals plus CE marking cover North American and European installations. No separate variant needed for UL 508 or CSA C22.2 panels.

Fieldbus integration — five protocols on one unit

PROFIBUS, PROFINET, Modbus RTU, Modbus TCP, and EtherNet/IP — all supported natively or via the standard communication module. The PROFINET interface also supports PROFIenergy for energy management during idle phases. No gateway needed for most plant networks.

Soft-start features for pump and conveyor duty

Voltage ramp and soft torque let you tune the acceleration profile. Pump ramp down decelerates gradually to prevent water hammer in pipeline systems. The minimum load is 15% of the smallest settable Ie — below that, the soft starter may not detect the motor current reliably. Auto-reset and remote reset by cycling the control supply are standard. No separate reset relay needed for unattended restart after a fault.

Mounting and panel clearances

Screw fixing to a vertical mounting surface; the unit can be rotated ±90° or tilted ±22.5° front-to-back. Minimum clearances: 100 mm upwards, 75 mm downwards, 10 mm forwards, 5 mm at the sides, 0 mm backwards. These are the ventilation and cable-bend allowances — ignore them and you'll derate the unit or trap heat.

Operating temperature and derating

Rated for -25 to +60 °C during operation, but derating applies above 40 °C. At 50 °C ambient, expect roughly 80% of the rated current; at 60 °C, about 60%. The derating curve is in the manual — factor it into the panel thermal design, especially if the soft starter shares an enclosure with other heat sources.