Siemens 3RW5215-1TC14

Siemens 3RW5215-1TC14 Soft Starter, 11.5 A, Trip Class 10A

MPN 3RW5215-1TC14
Active

Siemens SIRIUS 3RW5215-1TC14 soft starter, 200-480 V AC, 11.5 A minimum, Trip Class 10A (default) / 10E / 20E, with PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW5215-1TC14 specifications
ParameterValue
Mountingscrew fixing
Depth152 mm
Width170 mm
Height275 mm
Trip classCLASS 10 A (default) / 10E / 20E; acc. to IEC 60947-4-2
Service factor1
Digital output version2 normally-open contacts (NO) / 1 changeover contact (CO)

Product details

Trip Class 10A default — what it means for motor protection

The 3RW5215-1TC14 is a SIRIUS soft starter rated for a minimum motor current of 11.5 A and a rated operational voltage of 200 to 480 V AC. Its default Trip Class is CLASS 10A per IEC 60947-4-2, with selectable 10E and 20E curves. CLASS 10A means the starter must disconnect within 10 seconds at 7.2× the set current — the standard for standard-duty induction motors driving pumps, fans, and compressors where the load accelerates in under 10 seconds. For higher-inertia loads (centrifuges, long conveyors), switching to 20E buys 20 seconds of thermal headroom before tripping. The minimum load threshold is 15 % of the smallest settable Ie, so it handles lightly loaded motors without nuisance tripping. Service factor is 1 — no built-in overload margin beyond the set current.

Fieldbus flexibility — PROFIBUS, Modbus TCP, EtherNet/IP

This soft starter ships with PROFIBUS onboard and also supports Modbus RTU, Modbus TCP, and EtherNet/IP. That covers the three dominant industrial Ethernet protocols plus the legacy PROFIBUS fieldbus, so it fits into Siemens S7, Rockwell, or Modicon architectures without an external gateway. PROFIenergy is available when paired with the PROFINET communication module. Remote reset is achieved by cycling the control supply voltage off and on — no separate reset signal required.

Mounting and clearance — screw-fixed, 275 mm tall

Mounting is screw fixing on a vertical surface, with ±10° rotation and forward/backward tilt allowed. The enclosure measures 275 mm high by 170 mm wide by 152 mm deep. Clearance requirements: 100 mm above, 75 mm below, 10 mm in front, 5 mm to the side, and 0 mm behind — so it can sit flush against the back panel. Power terminals accept 2× (1.0 to 2.5 mm²) and 2× (2.5 to 10 mm²) solid conductors. Shock resistance is 15 g / 11 ms, dropping to 12 g / 11 ms if contact lifting is a concern.