Siemens 3RW5224-3TC14

Siemens 3RW5224-3TC14 Soft Starter, 20A min, 200-480V

MPN 3RW5224-3TC14
Active

Siemens SIRIUS 3RW5224-3TC14 soft starter, 200-480 V, 20 A minimum setting, Trip Class 10A (default) / 10E / 20E, screw fixing, 306 x 185 x 203 mm (HxWxD).

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW5224-3TC14 specifications
ParameterValue
Mountingscrew fixing
Depth203 mm
Width185 mm
Height306 mm
Trip classCLASS 10 A (default) / 10E / 20E; acc. to IEC 60947-4-2
Service factor1

Product details

20 A minimum setting and trip class — what drives the motor start profile

The 3RW5224-3TC14's minimum settable current is 20 A, which defines the lower bound of the motor full-load current it can protect. For higher-inertia loads like centrifuges or crushers, select Class 10E or 20E via the parameter menu — the longer trip time gives the motor headroom to accelerate without nuisance tripping. This means the same unit works on 230 V, 400 V, and 480 V systems without a hardware change — only the parameter set adjusts.

Fieldbus portfolio — five protocols in one hardware variant

This order code ships with onboard PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET — no separate communication module purchase required. The PROFINET interface supports PROFIenergy, which allows the controller to put the starter into an energy-saving idle state during production pauses.

Mounting and clearance — screw-fixed, not DIN-rail

Fastening is by screw fixing — the unit does not snap onto a DIN rail. Plan for four M6 screws into a backplate rated for the 306 × 185 × 203 mm envelope. Minimum clearance requirements: 100 mm above, 75 mm below, 10 mm forward, 0 mm backward, and 5 mm at each side. These gaps are for ventilation and arc-flash containment; crowding them derates the continuous current.

Active production — no LTB, no obsolescence signal

No pin-compatible successor exists because none is needed.

Approvals and ambient derating for global installations

Carries CE, UL, and CSA marks — accepted in European, US, and Canadian installations without additional agency review. In a 50 °C panel, expect to reduce the motor full-load current setting proportionally per the derating curve.