Skip to main content
Siemens 3RW5225-3TC05

Siemens 3RW5225-3TC05 SIRIUS Soft Starter, 200-600V

MPN 3RW5225-3TC05
Active

Siemens SIRIUS 3RW5225-3TC05 soft starter, 200-600 V, trip class 10A/10E/20E, PROFIBUS/Modbus TCP/RTU/EtherNet/IP, screw fixing, 306x185x203 mm.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW5225-3TC05 specifications
ParameterValue
Mountingscrew fixing
Depth203 mm
Width185 mm
Height306 mm
Trip classCLASS 10 A (default) / 10E / 20E; acc. to IEC 60947-4-2
Service factor1

Product details

The Siemens 3RW5225-3TC05 is a SIRIUS soft starter rated for a supply range of 200 to 600 V, with a minimum set current of 25.5 A and trip class 10A (default), 10E, or 20E per IEC 60947-4-2. Trip class 10A means it can handle a 10-second overload before tripping — standard for most pump and fan starts. If your motor has a longer acceleration time (high-inertia load like a centrifuge), switching to class 20E buys you 20 seconds before the thermal model trips. The default is 10A; you set it via the integrated HMI or fieldbus. That means if this lives in a non-ventilated panel next to a drive, expect to reduce the current setting or add forced air — the thermal model inside assumes free airflow at 40 °C. Fieldbus options are stacked: PROFIBUS, PROFINET (with PROFIenergy), Modbus RTU, Modbus TCP, and EtherNet/IP all on the same unit. No separate communication module needed for most networks — just wire the RJ45 or D-sub and set the node address. The PROFIenergy profile lets the PLC shut down the soft starter during idle periods to save panel power.

Mounts via screw fixing (not DIN rail) on a vertical surface, with ±10° tilt allowed forward or backward. Clearance requirements: 100 mm above, 75 mm below, 10 mm in front, 5 mm at the sides, 0 mm behind. That 100 mm upward gap is for heat plume rise — skimp on it and the internal thyristor heatsink will recirculate hot air, accelerating the derating curve. Dimensions are 306 mm high, 185 mm wide, 203 mm deep — roughly a 12x7x8 inch box. It's not a slimline unit; plan for a full-height sub-panel bay. The screw terminals accept up to the cable size needed for 25.5 A minimum, but the actual power terminals are sized for the full rated current of the unit.

Approvals include CE, UL, and CSA, covering most industrial markets in Europe and North America.

MPN
3RW5225-3TC05