Siemens 3RW5227-3AC15

Siemens 3RW5227-3AC15 SIRIUS Soft Starter, 40.5 A, 200-600 V

MPN 3RW5227-3AC15
Active

Siemens SIRIUS 3RW5227-3AC15 soft starter, 40.5 A minimum, 200-600 V rated, Class 10A/10E/20E, screw fixing, 306x185x203 mm.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW5227-3AC15 specifications
ParameterValue
Mountingscrew fixing
Depth203 mm
Width185 mm
Height306 mm
Trip classCLASS 10 A (default) / 10E / 20E; acc. to IEC 60947-4-2
Service factor1

Product details

Trip class and motor starting duty

The 3RW5227-3AC15 ships with a default trip class of CLASS 10A per IEC 60947-4-2, with selectable 10E and 20E curves for heavier starting loads like crushers or centrifuges where the acceleration time exceeds 10 seconds. Minimum load setting is 15% of the smallest settable Ie, so it handles lightly loaded motors without nuisance tripping on the start curve.

Mounting and panel clearance

Screw-fixing mount with a vertical surface orientation; the unit is rotatable ±90° and tiltable ±22.5° front-to-back, giving flexibility in tight enclosures. Clearance requirements are 100 mm upwards, 75 mm downwards, 10 mm forwards, 5 mm at the sides, and 0 mm backwards — plan the gland plate and cable duct accordingly. Overall dimensions are 306 mm height, 185 mm width, 203 mm depth — fits standard 600 mm deep enclosures with room for the main contactor and overload above or below.

Communication and control integration

Built-in PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET standard interfaces mean it drops into most plant networks without a separate gateway. PROFIenergy support is available when paired with the PROFINET communication module, allowing coordinated energy management during idle phases. Analog output is configurable as 4-20 mA (default) or 0-10 V via the High Feature HMI, giving the PLC a direct current or voltage signal proportional to motor current.

Environmental and compliance

Shock resistance is 15 g / 11 ms, dropping to 12 g / 11 ms if contact lifting is a concern — suitable for most industrial environments without additional vibration damping. Carries CE, UL, and CSA approvals, covering installations under IEC, North American, and Canadian codes without separate agency review.

MPN