Skip to main content
Siemens 3RW5236-2TC14

Siemens 3RW5236-2TC14 SIRIUS Soft Starter, 81 A, 200-480 V

MPN 3RW5236-2TC14
Active

Siemens SIRIUS 3RW5236-2TC14 soft starter, 81 A minimum, 200-480 V, Class 10A/10E/20E, screw fixing, 306 x 185 x 203 mm.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW5236-2TC14 specifications
ParameterValue
Mountingscrew fixing
Depth203 mm
Width185 mm
Height306 mm
Trip classCLASS 10 A (default) / 10E / 20E; acc. to IEC 60947-4-2
Service factor1

Product details

81 A minimum — what that means for motor starting

The 3RW5236-2TC14 is a SIRIUS hybrid soft starter rated for a minimum setting current of 81 A at 200-480 V. That 81 A floor governs the smallest motor you can protect — set the ramp below it and the starter won't engage. The trip class defaults to CLASS 10A per IEC 60947-4-2, with selectable 10E and 20E for longer acceleration profiles on high-inertia loads like centrifuges or crushers. The unit supports soft torque and pump ramp down, which means it can decelerate a pump gradually to avoid water hammer on shutdown — a feature that saves pipework and valves on water/wastewater lines.

Fieldbus and control integration

This soft starter ships with onboard PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET standard communication — no add-on module needed for most plant-floor networks. The PROFINET interface also supports PROFIenergy, letting the starter participate in coordinated energy-saving pauses during production breaks. Auto-reset and remote reset (by cycling the control supply voltage) are built in, so the starter can restart after a fault without a panel visit — useful for remote or unattended pump stations. Firmware updates are field-loadable, though the error logbook requires a special accessory.

Mounting and cooling — panel fit

Dimensions are 306 mm high, 185 mm wide, 203 mm deep. The unit mounts by screw fixing, not DIN rail, so budget for four M6 screws into a backplate. The mounting surface must be vertical, but the starter can be rotated ±90° or tilted ±22.5° front-to-back — useful when fitting into a tight enclosure corner. Clearance requirements: 100 mm above, 75 mm below, 10 mm forward, 5 mm at the sides, and 0 mm backward (flush to the backplate). Shock rating is 15 g / 11 ms, dropping to 12 g if contact lifting is a concern.

MPN
3RW5236-2TC14