Skip to main content
Siemens 3RW5248-6AC05

Siemens 3RW5248-6AC05 Soft Starter, 240 A, 200-600 V, SIRIUS

MPN 3RW5248-6AC05
Active

Siemens SIRIUS 3RW5248-6AC05 soft starter, 240 A minimum, 200-600 V AC, trip class 10A/10E/20E, PROFIBUS/Modbus/EtherNet/IP/PROFINET, screw fixing, 393 x 210 x 203 mm.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW5248-6AC05 specifications
ParameterValue
Mountingscrew fixing
Depth203 mm
Width210 mm
Height393 mm
Trip classCLASS 10 A (default) / 10E / 20E; acc. to IEC 60947-4-2
Service factor1
Digital output version2 normally-open contacts (NO) / 1 changeover contact (CO)

Product details

240 A minimum — the floor for motor sizing

The 3RW5248-6AC05 carries a 240 A minimum rated current, which sets the lower bound for motor full-load amps it can start. For a standard squirrel-cage motor at 400 V, that floor covers everything from about 110 kW up — but the real constraint is the trip class selection. Class 10E and 20E extend the thermal budget for higher-inertia loads such as centrifuges or crushers, where the start takes longer.

Voltage range and fieldbus — global panel fit

Rated 200-600 V, the unit covers 208 V through 575 V networks without a tap change — one SKU for North American 480 V and European 400 V installations. The wide range also absorbs line-side voltage sags common on weak grids. Fieldbus options include PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET. That covers most PLC ecosystems — Siemens S7, Rockwell ControlLogix, and Schneider M580 — without an external gateway. PROFIenergy support lets the starter coordinate with the controller during idle periods to shed load.

Ambient thermal limits — derating above 40 °C

In a hot mill or enclosed panel with other heat sources, the 240 A minimum may need to be reduced — the derating curve in the manual sets the actual ceiling. The 15 g / 11 ms shock resistance covers most industrial vibration profiles, including near rolling stands.

Mounting and enclosure clearance

Screw fixing, dimensions 393 mm high × 210 mm wide × 203 mm deep. Minimum clearance requirements: 100 mm above, 10 mm forward, 5 mm at the sides, 75 mm below — no clearance needed at the back. That 203 mm depth plus forward clearance means a 250 mm deep enclosure minimum for flush mounting. Mounting position is vertical surface, rotatable ±90° and tiltable ±22.5° front-to-back. That gives flexibility for tight panels but the derating note still applies — airflow direction changes with tilt.

MPN
3RW5248-6AC05