Siemens 3RW5513-3HF14

Siemens 3RW5513-3HF14 Soft Starter, 200-480 V, ATEX

MPN 3RW5513-3HF14
Active

Siemens 3RW5513-3HF14 soft starter, 200-480 V AC, ATEX/IECEx certified, trip class 10A/10E/20E/30E, PROFIBUS/Modbus/EtherNet/IP, fail-safe, analog output.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW5513-3HF14 specifications
ParameterValue
Mountingscrew fixing
Depth152 mm
Width170 mm
Height275 mm
Trip classCLASS 10 A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2
Service factor1.15

Product details

ATEX-certified soft starter with multi-protocol fieldbus

The Siemens 3RW5513-3HF14 is a soft starter certified for use in explosive atmospheres (ATEX Yes, IECEx Yes) and carries UL and CSA approvals — a rare combination that lets it serve both European Zone-rated installations and North American UL-listed panels without a separate barrier device. Rated supply voltage is 200-480 V AC (50/60 Hz), covering the common low-voltage motor distribution range across global sites.

Trip class and motor protection flexibility

Trip class is selectable between CLASS 10A, 10E (default), 20E, and 30E per IEC 60947-4-2 — the 10A/10E setting protects standard squirrel-cage motors during start, while 20E or 30E accommodates high-inertia loads (centrifuges, crushers) that need a longer acceleration ramp without nuisance tripping. Accuracy Class 5 per IEC 61557-12 means the current measurement error stays within ±5 % of reading — sufficient for motor overload protection but not for revenue-grade energy metering. The integrated fail-safe function (with fail-safe: 1) supports SIL-rated safety circuits; the safe state is an open load circuit, which means the output de-energises to a known off condition on fault.

Fieldbus connectivity and commissioning tools

Supports PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP on the same hardware — no swapping of communication modules needed when the control network changes. Built-in event list, error logbook, and trace function let a commissioning engineer capture start-up current profiles and fault sequences without an external data logger. Analog output is configurable as 4-20 mA (default) or 0-10 V, feeding motor current or torque signals to a PLC analog input or local panel meter.

Mounting dimensions and clearance requirements

Width 170 mm, height 275 mm, depth 152 mm — the footprint is sized for a standard 400 mm-wide enclosure backplate with room for a line-side contactor and overload relay on the same DIN rail. Required clearances: 100 mm upwards, 75 mm downwards, 5 mm at the side, 10 mm forwards, 0 mm backwards — the zero rear clearance means it can sit flush against the backplate, saving depth in shallow enclosures.