Siemens 5SU1354-0LB13

Siemens 5SU1354-0LB13 SENTRON RCBO, 13 A, B Curve, 10 kA

MPN 5SU1354-0LB13

Siemens SENTRON 5SU1 RCBO, 1P+N, 13 A rated current, B tripping characteristic, 10 kA breaking capacity per EN 60898, AC fault current type, 2 MW, IP20.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

5SU1354-0LB13 specifications
ParameterValue
Poles2
Temp operating max55 °C
Temp operating min-25 °C
Depth77 mm
Width36 mm
Height90 mm

Product details

The Siemens 5SU1354-0LB13 is a SENTRON RCBO — a combined residual-current and overcurrent protective device — in a 1P+N configuration, meaning it switches the line conductor and monitors the neutral for ground faults while providing overcurrent protection on the line side only.

Above that, the device derates: 12.48 A at 40 °C, 12.22 A at 45 °C, 11.96 A at 50 °C, 11.57 A at 55 °C, 11.31 A at 60 °C, 10.53 A at 65 °C, and 10.01 A at 70 °C. The fault-current type is AC-only (senses sinusoidal residual currents). For pulsating DC or smooth DC fault currents, a type A or type B RCBO would be needed. Energy limiting class 3 indicates it lets through less let-through energy (I²t) than class 1 or 2 devices, reducing stress on downstream cables and components during a fault.

It accepts solid or stranded conductors from 0.75 mm² up to 35 mm² — covering everything from 1.5 mm² lighting circuits to 10 mm² feeder tails. The supply can enter from either top or bottom, which simplifies busbar routing in a crowded distribution board. IP20 with the distribution board installed and conductors connected; the front face is finger-safe only when the board cover is closed. Mounting position is any — the device operates correctly upright, sideways, or inverted, which helps when the DIN rail is oriented vertically.

The RCBO is designed to EN 60898 (the European standard for circuit-breakers for overcurrent protection in household and similar installations) and carries the CE marking. The device is classified per DIN EN 61346-2 and DIN EN 81346-2 as function code F (protective device). The minimum test voltage for the integral test circuit is 195 V AC — the test button will not operate correctly below that line voltage.

MPN
5SU1354-0LB13