Skip to main content
Siemens 6ES7307-1BA01-0AA0

Siemens 6ES7307-1BA01-0AA0 SITOP Power Supply, 2 A, ATEX, UL

MPN 6ES7307-1BA01-0AA0
NRND

Siemens SITOP power supply, 6ES7307-1BA01-0AA0, 2 A rated output, 120/230 VAC input, ATEX II 3G, IECEx, cULus listed, IP20.

$210.00 – $324.97 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

6ES7307-1BA01-0AA0 specifications
ParameterValue
Fuse protection typeT 1.6 A/250 V (not accessible)
Voltage24 V
Power48 W
Frequency47 ... 63 Hz
Phases1-phase
IP ratingIP20
MountingCan be mounted onto S7 rail
Depth120 mm
Width40 mm
Height125 mm
Efficiency84%

Product details

The 6ES7307-1BA01-0AA0: This SITOP power supply delivers a rated output of 2 A (0 to 2 A range) at SELV levels per EN 60950-1 and EN 50178, making it suitable for powering 24 VDC control loads in a Siemens S7-300 rack or similar automation island. Input accepts 120 VAC (85 to 132 V) or 230 VAC (170 to 264 V) at 47 to 63 Hz — covers global line voltages without a tap change. The ATEX II 3G Ex nA nC IIC T4 Gc and IECEx Ex nA nC IIC T4 Gc ratings mean it is certified for use in Zone 2 gas hazardous areas (non-sparking, non-incendive) with T4 temperature class (≤135 °C surface). The cULus Class I, Div. 2 approval (File E330455) extends that to North American Division 2 locations. Galvanic isolation with safety extra-low output voltage ensures the 24 VDC side is touch-safe and isolated from the mains — critical for protecting downstream PLC I/O and field sensors.

Mounting and wiring checklist

Fastens onto the S7-300 DIN rail (standard 35 mm profile). Clearance: 40 mm top and bottom, 0 mm left and right — no side gap needed, but plan for airflow above and below. Output terminals: L+, M — two screw terminals each for the same wire range. Strip length and torque per standard practice. Recommended upstream protection: a 3 A characteristic C miniature circuit breaker in the feeder. Operating temperature range 0 to 60 °C with natural convection — no forced cooling required within that range. Storage and transport range -40 to +85 °C.

CE marked. cULus-Listed to UL 508 and CSA C22.2 No. 142 (File E143289). EAC approved. FM registered for Class I, Div. 2, Groups A, B, C, D, T4. MTBF at 40 °C: 2,320,078 hours — reflects a robust design for continuous industrial operation. Maximum I²t value: 1 A²·s — relevant for fuse coordination and inrush current assessment.

MPN
6ES7307-1BA01-0AA0