MPN 6ES7516-3FN01-0AB0

Siemens SIMATIC S7-1500 CPU 1516F-3 PN/DP, 6ES7516-3FN01-0AB0, failsafe controller with PROFIsafe, 32 kB process image each way, 2x PROFINET + 1x PROFIBUS, -40 to 70°C.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

6ES7516-3FN01-0AB0 specifications
ParameterValue
Product typeHardware clock
Depth129 mm
Width70 mm
Height147 mm
Backup time6 wk; At 40 °C ambient temperature, typically
Screen diagonal6.1 cm

Product details

Failsafe CPU with integrated PROFIsafe

The 6ES7516-3FN01-0AB0 is a failsafe CPU supporting FBD and LAD programming including failsafe blocks. Safety logic is written in the same editor as standard logic. PROFIsafe V2.4 / V2.6 is onboard, so this CPU talks safety over PROFINET without an extra F-host module. The safety application rides the same cable as standard I/O — cuts the wiring count in half on a safety zone.

Process image and I/O capacity

32 kbyte of inputs and 32 kbyte of outputs land in the process image. For a mid-size line that means you can map roughly 500 digital channels or a mix of analog and fast counters without hitting the I/O ceiling. The 16-channel onboard DI handles local interlock signals — the rest goes over PROFINET. Up to 8 communication modules or CPs (PROFIBUS, PROFINET, Ethernet) can be inserted total. If you need more than 8 fieldbus drops, you are looking at a distributed IO architecture rather than stuffing the rack.

Network redundancy and protocols

MRP (Media Redundancy Protocol) is supported with the CPU acting as Automanager, Manager, or Client per IEC 62439-2 Edition 2.0. In a ring topology the reconfiguration time stays under 200 ms — enough for most conveyor and material-handling lines to ride through a cable break without dropping the safety zone. MODBUS TCP is native — no extra gateway needed when talking to a VFD, flow meter, or third-party HMI. Also carries DHCP, DNS, DCP, SNMP, LLDP, HTTP/HTTPS for standard IT integration into a plant network.

Environmental range and physical fit

The 70 mm wide, 147 mm tall, 129 mm deep footprint fits a standard 80 mm DIN-rail slot; leave 20 mm clearance above for the heat sink fins.