ABB 1SFA895003R7000 — Soft Starters

ABB PST37 1SFA895003R7000 Soft Starter, 37 A, 18.5 kW

MPN1SFA895003R7000
Obsolete

ABB PST37 series, 1SFA895003R7000 soft starter, 37 A rated operational current in-line, 18.5 kW at 400 V, 100-250 V AC control supply, screw terminals.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

1SFA895003R7000 key specifications
ParameterValue
Terminal typeScrew Terminals
Product main typePST37
VoltageMain Circuit 400 ... 690 V AC
Initial voltage during start30 ... 70 %
Step down voltage special ramp100 ... 30 %
Rated control supply voltage100 ... 250 V AC
Rated control circuit voltageDC Operation 24 V
Current limit function1.5 ... 7xIe
Starting capacity at maximum rated current ie3xIe for 15s
Rated operational current - In-Line connection37 A
Rated operational current - inside delta connection64 A
Rated operational power - In-Line connection(400 V) 18.5 kW

All specifications

1SFA895003R7000 additional specifications
ParameterValue
Rated operational power - inside delta connectionat 400 V 30 kW
Rated frequency50/60 Hz
IP ratingacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
ProtocolFiledBusPlug(Standard)
Switch for inside delta connectionYes
Material compliance (Conflict minerals reporting template)9AKK108467A5658
Ramp time0 ... 120 second [unit of time]
Analog outputs0...10 volts
Run signal relayYes
Tightening torqueControl Circuit 0.5 N·m
Fault signal relayYes
Overload protectionBuild-in electronic overload protection
By-pass signal relayYes
Overload signal relayYes
Ambient air temperatureOperation 0 ... +50 °C
Service factor percentage115 %
Object classification codeQ
Signal indication faultRed
Integrated electronic overloadYes
Connecting capacity main circuitRigid 1 x 10 ... 95 mm²
Connecting capacity supply circuitRigid 1 x 2.5
Signal indication protectionYellow
Connecting capacity control circuitRigid 1 x 2.5 mm²
Popular downloads (Instructions and manuals)1SFC132003M0201
Popular downloads (Data sheet, technical information)1SFC132005C0201

Product details

Rated for the motor, not just the nameplate

The ABB PST37 1SFA895003R7000 is a soft starter sized for a 37 A in-line motor load — that's 18.5 kW on a 400 V three-phase supply. In an inside-delta configuration it handles 64 A and 30 kW, which is the wiring you'd use for a larger motor where the starter sits inside the delta loop to reduce the current through the main contacts. The main circuit is rated 400 to 690 V AC, so it covers standard European 400 V and 690 V industrial networks without a separate voltage tap. Built-in electronic overload protection is integrated — no separate overload relay needed in the panel. The current limit function is adjustable from 1.5 to 7 times the set motor current, which lets you tune the start for high-inertia loads or soft-coupled conveyors. Ramp time spans 0 to 120 seconds, with an initial voltage during start adjustable 30 to 70 % and a step-down special ramp from 100 to 30 %. That's enough range for most pump, fan, and compressor starts without external timers.

Control wiring and signals

Control supply voltage is 100 to 250 V AC, with a separate 24 V DC control circuit available for the logic. Screw terminals on the control circuit accept 1 x 2.5 mm² rigid; tighten to 0.5 N·m. The main circuit terminals accept 1 x 10 to 95 mm² rigid. Communication is via a standard FieldBusPlug — the PST37 accepts a plug-in fieldbus adapter, so you can add PROFIBUS, DeviceNet, or Modbus without changing the base unit. Four signal relays are built in: run, fault, by-pass, and overload. Each provides a dry contact for the PLC or status lamp. A red LED indicates a fault condition; a yellow LED signals protection activation. The analog output is 0 to 10 V, typically used to feed a speed or current signal to a remote meter or drive controller.

Frequently asked questions

What is the ramp time range on this PST37 soft starter?

The ramp time is adjustable from 0 to 120 seconds, with initial voltage during start from 30 to 70 % and a step-down ramp from 100 to 30 %.

What communication protocol does 1SFA895003R7000 use?

The base unit accepts a standard FieldBusPlug, which allows a fieldbus adapter module to be added for PROFIBUS, DeviceNet, Modbus, or other protocols without changing the starter.

Where can I buy 1SFA895003R7000 and what is the lead time?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead time and price.

What compliance documentation does ABB provide for this soft starter?

The part carries a WEEE classification as small equipment (B2B) and RoHS information is noted as no declaration needed. The datasheet reference is 1SFC132005C0201 and the manual is 1SFC132003M0201.

MPN
1SFA895003R7000